STEP 2:
Strip 95mm (3.75in) of cable jacket, and trim back any
filler. Strip conductor insulation 10mm (0.39in) from
ends. Feed wire through end cap, rubber gland, and
gland cap. Install cord clamp and tighten to 20 in-lbs
(2.3 N-m) so that cable jacket protrudes 5mm past
the end of the cord clamp.
Slide together end cap, rubber gland, and gland cap
assembly, before fastening with three M4 socket
head cap screws torqued to 20 in-lbs (2.3 N-m).
NOTE:
Electrical cord used must be 14 Gauge/3 Conductor
SOOW with an outer diameter between 13mm [0.51”]
and 14.2mm [0.56”]. SOOW cord must be rated for
600V/90˚C or higher.
Maximum string length must not exceed 300 ft.
Maximum number of lighting modules must not exceed
30 units on a single string.
STEP 3:
Connect each conductor into appropriate connectors
STEP 4:
Wrap excess conductor inside cap and gently rotate to
compress wires (without pinching them) till the assem-
bly holes align with the core and internal wires are not
strained or pinched.
Attach End Cap Assembly to the core with the supplied
M4 socket head cap screws (3) with M4 hex driver
torque to 2.3 N-m (20 in-lbs).
STEP 5:
Repeat steps 2-4 for other side of module.
INSTALLATION (CONT.)
TM
Nemalux
I N D U S T R I A L
LS Series
rev. A-20
5-6
www.nemalux.com | [email protected] | Tel 403•242•7475 | Fax 403•243•6190
MADE IN CANADA
Step 4
Step 2
85mm
10mm
5mm