PROBLEM:

 

Nozzle stopper (valve seat) continues to leak when closed.

SOLUTION:

 1. Adjust valve seat to assure even contact on nozzle seal surface.

a. Disconnect actuator pin      .

b. Loosen the valve seat locking nut     .

c. Rotate lever assembly      to closed position and hold valve seat

lightly against nozzle seal surface. Adjust valve seat      by rotating the

stopper in or out as required to achieve full contact with the nozzle seal surface.

d. Tighten the locking nut      .

2. Adjust linkage to assure adequate closure force.

a. Adjust linkage assembly at ‘A’ so that 12-15 pounds force is required to

push link ‘B’ against closure stop (disconnect and reconnect lower toggle

pin      during adjustment as required to check closure).

b. Reconnect actuator pin      .

PROBLEM:

 

Nozzle stopper won’t clear stream when open.

SOLUTION: 

Adjust actuator position to assure complete opening.

a. Loosen jam nut   

 

  .

b. Hold nozzle lever      in the fully open rest position.

c. Rotate actuator assembly        toward main elbow until rest buttons contact

and all play is removed from the linkage. Rotate further as needed until

drain hole and hose fitting port are oriented to the bottom.

d. Tighten jam nut   

 

  .