NW511
19
6 MALFUNCTIONS SHOWN ON THE DISPLAY (FOR
THE TECHNICIAN)
The
warewasher
is
able
to
identify
a
number
of
malfunctions
and
show
them
on
the
display.
If
the
problem
persists
after
the
warewasher
has
been
switched
off
and
back
on,
proceed
as
described
below:
E.1
Boiler
temperature
probe
malfunction
Boiler
temperature
probe
disconnected
or
not
working
E.2
Tank
temperature
probe
malfunction
Tank
temperature
probe
disconnected
or
not
working
E.3
Water
intake
malfunction
Water
intake
not
completed
in
the
maximum
time
allowed
Check
dynamic
pressure
in
intake
system,
clean
water
intake
filter.
If
the
problem
persists:
‐
tank
pressure
switch
has
failed
(continuous
empty
reading)
‐
leak
from
pipe
connected
to
air
trap
‐
drain
siphon
blocked
‐
the
tank
is
empty
due
to
siphoning
when
the
drain
pump
is
not
running
also
controls:
if
tank
and
boiler
pressure
switch
properly
if
the
rubber
pipes
are
connected
correctly
if
the
air
trap
is
clogged/dirty
if
the
rinse
pump
running
correctly
E.4
Boiler
overheating.
Reduce
boiler
temperature
<
80°.
Circuit
board
relay
failed,
check
circuit
board
and
inspect
boiler
heating
element
for
damage
E.5
Tank
overheating
Reduce
boiler
temperature
<
58°.
Circuit
board
relay
failed,
check
circuit
board
and
inspect
tank
heating
element
for
damage
Содержание NW511
Страница 1: ...PROFESSIONAL DISHWASHER...
Страница 12: ...NW511 12 Figure 1 Appliance single phase electrical system diagram...