N1500i FACS Manual
7
Part No. 729-110-053 V.1.03
© 2018 Nelson Stud Welding, Inc. All rights reserved.
Warning!
Connect the workpiece ground cable plug into the proper socket
of the Nelweld N1500i.
The connection must be secured by a full clockwise turn of the
workpiece ground cable plug.
1.2.6 Connection of the Workpiece Weld Cable
The welding current returns through the workpiece ground cable,
which must be connected to the workpiece ground cable socket of
the Nelweld N1500i.
Workpiece Weld Cable Connection (X3)
Use cable resistance monitor (see section 3.15) to continuously monitor loose
connector fault condition in production.
1.2.7 Connection of the shielding gas (Option)
Prerequisites:
The Nelweld N1500i has an optional shielding gas valve combination
kit that can be factory or field installed.
The connected weld gun needs to be equipped with the optional special
equipment for shielding gas.
Standard Mode:
When the gun with manual stud-loading is connected, the tubes from
the gas source and the weld gun must be directly connected to the
Nelweld N1500i.
Note!