Memory M2
♦
Press the M button for 5 seconds, and the flashing icon M1 appears. Now press the CH
button and the icon M2 will appear flashing on the display.
♦
Scroll through the channels using the
▲▼
arrows, and the various channels will flash. To
enter the channel in the memory, press the STOP button, the channel stops flashing and
becomes steady-on; carry out this operation for all the channels you would like to store, up
to a maximum of 10 channels.
♦
To exit the channel storing mode, press the M button again for at least 1 second.
♦
To erase the memory, go to the channel 00 and press the STOP button. After the memory
has been erased, all the channels start flashing. To exit, press the M button again for 1
second.
Checking the composition of a memory sequence
♦
From the wait state, press the M button; the M1 icon will be activated.
♦
The stored sequence of channels appears on the display (e.g.: 1-2-3-4-pause, 1-2-3-4-
pause, etc.).
Control of a stored sequence - M1 and M2 Memories.
Starting from the wait state, press the M button and the steady-on M1 icon will appear on the
display; using the
▲▼
buttons activates the function, transmitting the command to the channels of
the M1 sequence. The stored channels scroll cyclically and continuously on the display.
Starting from the wait state, press the M+CH button and the steady-on M2 icon will appear on the
display; using the
▲▼
buttons activates the function, transmitting the command to the channels of
the M2 sequence. The stored channels scroll cyclically and continuously on the display.
The STOP button stops the command.
Press the M button once to exit from the memory sequence control state, and the M1 or M2 icon
disappears; now it is possible to activate the commands of all the individual channels.
F1 and F2 Function buttons
The F1 and F2 function buttons are dedicated exclusively to the applications controlling the
dedicated motors constructed to carry out certain tasks in complete autonomy, that is:
A. Motors dedicated to ventilation on sash / hopper windows;
B. Motors for applications controlling the S
YSTEM
T
RIS
.
A. Sash / hopper - ventilation application
Before each operation with the F1 and F2 functions, the desired channel should be selected
and then the function can be executed:
♦
Sash function. Press the F1 button; the steady-on F1 icon appears on the display.
Pressing the
▲
button activates the “Sash Function”. The window can be opened
manually.
To cancel the F1 function, first close the window and then press the F1 button; the icon
disappears from the display.
♦
Ventilation function. Press the F2 button; the steady-on F2 icon appears on the display.
Pressing the
▲
button activates the automatic “Ventilation Function”.
To cancel the F2 function, press the F2 button; the F2 icon disappears from the display.
Once inside the menu of one of the two “memory groups” (M1 or M2), whenever
the F1 or F2 button is pressed, the respective steady-on icons appear on the
display (M1, M2, F1, F2). This means that the respective group of channels can
now be controlled.