11.  RAIN DETECTION SENSOR 

The rain sensor should be installed outside on the window frame and fixed with a screw 
or  weather-resistant  adhesive  system.  The  device  acts  only  on  the  commands  of  the 
chain actuator. 

Warning

.  The  command  coming  from  the  rain  sensor  prevails  over  any  other 

command; if a stable switch is assembled with the manual control and forced opening is 
instructed, after having reached the opening stroke-end the window closes again, then 
it opens again, then closes again, etc. In order to prevent this problem from arising, do 
not assemble a stable control switch.

 

As described above in Chapter 9 (Electrical connection), a rain sensor model 

NRS1

 can 

be connected to the KATO ADV RADIO chain actuator with radio control. 
The  detector  is  capacitive  sensor  equipped  with  a  heater  in  order  to  render  the 
detection area insensitive to the formation of dew, humidity and ice and allow it to dry 
quickly after rainfall. 

NRS1

 is a universal sensor with relay output  and  voltage-free change-over contact 

(it 

can also be used by other systems)

, with a heater that operates below +4 °C.  

If  necessary,  the  heater  can  be  excluded  by  a  dip-switch.  The  5-conductor  cable 
provided is 5 m long, with a highly weather-resistant PVC sheath which is also non fire-
propagating and resistant to UV radiation. 

12.  PREDOMINANCE OF THE COMMANDS 

The rain sensor intervenes when it rains regardless of the state of the commands, i.e., 
the closing command due to rain, if activated, prevails over any manual command. 

13.  PROGRAMMING ACTUATOR 

13.1.  Limit switches at opening 

Four (4) positions can be selected for the limit switch of the outgoing chain.  
To  program,  adjust  the  two  dip-switches  near  left  terminal  board,  as  indicated  in  the 
following table. 

1

2

110

OFF

OFF

200

ON

OFF

300

OFF

ON

400

ON

ON

Limit switch at:       

(mm)

Dip-switch n°

 

After  the  limit  switches  have  been  programmed,  run  a  few  check  manoeuvres.  In  the 
event of error, programming can be repeated to give the desired track run. 

The actuator comes from production set on longer stroke (400 mm), dip-switch 1 in ON; 
dip-switch 2 in ON

13.2.  Limit switches at closure 

The  limit  switch  at  closure  is  automatic,  electronically  operated  and  cannot  be 
programmed.  The  actuator  stops  when  the  charge  is  absorbed  when  the  window  is 
completely closed and the weather stripping is completely depressed.  

12 

 

Attention

.  The  actuator  at  maximum  charge,  exercises  a  force  enough  to 

crush fingers in the event of distraction. 

After  each  closure  or  intervention  of  the  electrical  protection  mechanism,  the  chain 
moves in the opposite direction for around 1,0/1,5 mm. This is to loosen the tension of 
the mechanical parts and gives correct pressure to the weather stripping.

 

14.  ASSEMBLY 

These indications are intended for the attention of technicians and specialized 

personnel. Basic job and safety techniques are therefore not included. 

All preparatory operations, assembly and electrical connections must be carried out by 
technical and specialized personnel to guarantee best performances and good function 
of the KATO ADV RADIO chain operated actuator. 
First of all, please check that the following fundamental points have been satisfied: 

 

Before installing the actuator, check that the moving parts of the window on which it 
is  to  be  installed  are  in  perfect  working  condition  and  that  they  open  and  close 
properly and are well balanced (where applicable).  
Check  that  the  electrical  supply  used  corresponds  to  the  indications  on  the 
“TECHNICAL DATA” label attached to the machine and that the given temperature 
range is compatible with the place of installation. 
Actuator  specifications  must  be  sufficient  for  movement  of  the  window  without 
encountering any obstacle. The limits indicated in the technical data table must not 
be  superseded 

(page  7)

  and  the  most  appropriate  stroke  should  be  selected. 

Calculations should be checked using the formula indicated on 

page 5.

 

Ensure that the actuator has not been damaged during transport, first visually and 
then by powering in both directions. 
Check  that  the  width  of  the  inside  of  the  window  (where  the  actuator  is  to  be 
assembled) is over 405 mm, otherwise the actuator should not be installed. 
Check that  once  the actuator  has  been  installed the  distance  between  the  fixed 
part of the window frame (where the actuator is to be assembled) and the mobile 
part  of  the  window  frame  (where  the  bracket  is  to  be  fixed)  is  greater  than  or 
equal to 0 mm. If this is not the case the actuator will not function correctly as the 
window  will  not  close  correctly.  If  required,  add  additional  thickness  below  the 
support brackets to reset the quota.

 

14.1.  Preparation of actuator for assembly 

Before starting assembly of the actuator, prepare the following material for completion, 
equipment and tools.  

 

For  fixing  onto  metal  window  frames:  M5  threaded  inserts 

(6  pieces)

,  M5x12  flat 

headed metric screws 

(6 pieces)

 

For  fixing  onto  wooden  window  frames:  self-threading  screws  for  wood  Ø4.5 

(6 

pieces)

 

For fixing onto PVC window frames: self-threading screws for metal Ø4.8 

(6 pieces)

 

Equipment  and tools:  measuring  tape,  pencil,  drill/screwdriver,  set  of  drill heads  for 
metal, insert for screwing in, electricians pliers, screwdrivers. 

Содержание KATO ADV RADIO

Страница 1: ...air or adjustment is required CAUTION if the power cable is damaged it must be replaced by qualified personnel from a service centre authorised by the manufacturer CAUTION Disconnect the power supply...

Страница 2: ...he supplier of the complete system retains full liability For systems installed at a height of less than 2 5 m above floor level or other levels accessible to users the manufacturer supplier of the wi...

Страница 3: ...lled by an electronic function device Window opening can be programmed to open at 110 200 300 and 400 mm see respective chapter During closure the end course uses a self regulating electronic process...

Страница 4: ...alternating current of 110 230V with a frequency of 50 60 Hz The actuator is already equipped with a power supply cable which is 2 meters long The cable has two colored conductors Phase brown and Neut...

Страница 5: ...es of quick flashes for about 1 second then the LED will go out and remain at rest 10 10 1 2 Erasing the radio memory To completely erase the memory of the radio remote control on the machine press th...

Страница 6: ...the electrical protection mechanism the chain moves in the opposite direction for around 1 0 1 5 mm This is to loosen the tension of the mechanical parts and gives correct pressure to the weather stri...

Страница 7: ...bly on transom window Aside the drawing of specific application using accessories provided For different mountings please contact manufacturer Before starting check that there are at least two mechani...

Страница 8: ...cases it flashes in different ways depending on the signal it is emitting the different flashing modes indicate the precise behavior of the actuator during the programming of the machine radio remote...

Страница 9: ...ing as established from laws in force on recycling The device is mainly made from the following materials aluminium zinc iron plastic of various type cuprum Dispose materials in conformity with local...

Страница 10: ...irettiva sulla restrizione dell uso di determinate sostanze pericolose nelle apparecchiature elettriche ed elettroniche Direttiva RoHS Restriction of the use of certain hazardous substances Directive...

Отзывы: