7
The plate data is displayed on an adhesive label placed on the outside of the casing,
which must remain intact and visible.
The main information it displays includes: manufacturer's address, product name -
model number, technical characteristics, production date and serial number.
In the event of a complaint, please indicate the serial number (SN) displayed on the
label. An explanation of the symbols used on the label to abbreviate the technical
characteristics is given in the table in the chapter on “TECHNICAL DATA”.
6. TECHNICAL DATA
MODEL
KATO ADV RADIO
Force exerted by thrust and traction (F
N
)
300 N
Strokes (S
V
)
110, 200, 300, 400 mm
Power supply voltage (U
N
)
110-230V~ 50/60 Hz
Rated absorbed current (I
N
)
0,31 A - 0,24 A
Current consumption with no charge
0,084 A - 0,042 A
Charge absorbed at nominal load (P
N
)
23-27 W
No load speed
15,7 mm/s
No load duration
(400 mm)
25 s
Electrical insulation
Class II
Type of service (D
R
)
2 cycles
Working temperature
- 5 + 65 ºC
Protection index
IP30
Adjustment of socket at casing
Autopositioning
Holding nominal force
(it can vary according to
the chosen brackets)
1600 N
Connection of two or more devices in parallel
YES
Limit switch stop at opening
Electronic by means of dip-switches
Limit switch stop at closure
At absorption of charge
Dimensions
386,5x59x37
Weight
1,000 kg
Any information reported in this table is not binding and may be susceptible to variations without
notice
7. ELECTRIC POWER SUPPLY
Warning. Check that the electric power supply used corresponds to that
specified on the “technical data” label attached to the machine.
The manufacturer cannot be held liable for damage due to an application which is
incorrect or non-compliant with regulatory requirements.
The actuator is powered by a mains voltage, in alternating current, of 110-230V~ with a
frequency of 50/60 Hz.
The actuator is already equipped with a power supply cable which is 2 meters long. The
cable has two colored conductors: Phase (brown) and Neutral (sky-blue).
The connection between the line and the power supply cable of the actuator must be
protected by a magnetothermic switch between the line and actuator.
8
7.1. Selecting the cross-section of electric power supply cables
The cross-section of the electric power supply conductors must comply with current
standards on electrical systems, without prejudice to standard EN 60335 for connected
electrical devices.
8. ELECTRIC POWER SUPPLY AND SENSOR CONNECTION
8.1. Electric power supply cable
The power supply cable is already wired to the actuator. It is used for the electric
power supply of the system and should be connected to the electricity mains. The
power supply cable has two conductors: sky-blue, brown.
8.2. Cable entry to the terminal block
The cables entering on the left, in the same cable
feedthrough, are the following low-voltage cables:
Rain sensor cable
(five conductors)
.
Manual open/close control cable.
After the wiring is completed
(see the “Electrical
connection” chapter)
and the cables and cable
feedthrough are arranged properly, it is
recommended that the cable entry be sealed with
a drop of silicone; this will prevent humidity or
water from entering.
9. ELECTRICAL CONNECTION
E
LECTRIC SHOCK HAZARD
.
Before beginning any work on the machine's wiring, make certain that the
electric power has been disconnected; failure to observe this rule may
compromise safety.
Cable entry to the terminal block
No connection to the symbols indicated to the
side. FUNCTION NOT PRESENT in this
system
Connection of the rain detection sensor, model
NRS1
(five conductors)
:
Red (+) connected to
+15V
,
Black (-) connected to
-15V
,
Blue (N.O. contact) connected to “
PIOGGIA
”,
Green (common) connected to
-15V
,
Violet (N.C. contact) not used and should be
electrically isolated.