ATTUATORE A CATENA 

Forza 250N – Corsa massima 360 mm 
Alimentazione elettrica 100-240V~ 50/60Hz – 24V

 

 

INSTRUCTION MANUAL 

CHAIN ACTUATOR 

Force 250N – Maximum stroke 360 mm 
Electrical feeding 100-240V~ 50/60Hz – 24V

 

 

BETRIEBSANLEITUNG 

KETTENANTRIEB 

Kraft 250N – Maximalhub 360 mm 
Spannungsversorgung 100-240V~ 50/60Hz – 24V

 

 

 

 
 

 

DE 

IT 

EN 

 
 
 
 
 
nekos

 products have been manufactured in accordance with safety standards and conforms to the 

stipulations of current standards in force.  
When correctly assembled, installed and used according to the present instructions, they will not 
generate any danger for persons, animals or items.  
 
 
 
 

Symbols used in the manual 

 

DANGER 

This indication draw the attention about potential dangers for 
safety and health of peoples and animals. 

 

INFORMATION 

This information give further suggestions. 

 

ATTENTION 

This indication draw the attention about potential dangers for 
the product itself. 

 

WARNING 

This indication draw the attention about potential damages to 
goods. 

 

ENVIRONMENTAL 

INSTRUCTION 

Environmental  indication  draw  the  attention  about  potential 
dangers for the environment. 

 

 

English ................................................................................................................... 14 

1.  Security rules ............................................................................................................................ 14 
2.  Formulas and recommendations for installation  ...................................................................... 15 
3.  Technical information about function ........................................................................................ 16 
4.  Manufacture and applicable standards or regulations .............................................................. 16 
5.  Technical data .......................................................................................................................... 16 
6.  Id plate and marking data ......................................................................................................... 17 
7.  Electrical power supply ............................................................................................................. 17 
8.  Instructions for assembly .......................................................................................................... 17 
9.  Electrical connections ............................................................................................................... 20 
10. Programming the actuator ........................................................................................................ 21 
11. Checking for correct assembly ................................................................................................. 21 
12. Emergency manoeuvres, maintenance or cleaning .................................................................. 21 
13. Troubleshooting ........................................................................................................................ 22 
14. Environmental protection .......................................................................................................... 22 
15. Certificate of guarantee ............................................................................................................ 22 
16. Declaration of incorporation (for a partly completed machine) and EC declaration of 

conformity ................................................................................................................................. 34 

 
 
 
 
 
 
 

Содержание KATO 253

Страница 1: ...and animals INFORMATION This information give further suggestions ATTENTION This indication draw the attention about potential dangers for the product itself WARNING This indication draw the attention...

Страница 2: ...nsory or mental capabilities or lacking experience and knowledge Do not allow children to play with the fixed controls and keep any remote control units out of their reach The actuator is destined exc...

Страница 3: ...4 s 27 s Double electrical insulation YES Low tension Type of service S2 of 3 min Operating temperature 5 65 C Protection index for electrical devices IP30 Adjustment of connection to window frame Aut...

Страница 4: ...Attention for non coplanar window frames cut the grey part of the template along the red line and apply onto the mobile part of the window frame taking care to keep it in the same reference position f...

Страница 5: ...e 2 marks 360 mm stroke Attention never select 360 stroke when actuator is at 240 end stroke inner selector can irremediably brakes 10 2 Stroke end at closure The stroke end at closure is automatic an...

Страница 6: ...y of the purchaser 34 DECLARATION OF INCORPORATION FOR A PARTLY COMPLETED MACHINE AND EC DECLARATION OF CONFORMITY Hereby the Manufacturer Nekos Srl Via Capitoni 7 5 36064 Mason Vicentino Vicenza Ital...

Страница 7: ...36 NEKOS S r l Via Capitoni 7 5 36064 Mason Vicentino VI ITALY 39 0424 411011 Fax 39 0424 411013 www nekos it info nekos it...

Отзывы: