PRODUCT DESCRIPTION
Air Bottle Jack is designed for lifting, but not sustaining, loads capacity 20ton.
It can be used
vertically or angled to 5 degreed from vertical position.
After lifting, loads must be immediately
supported by appropriate means. The jack is not recommended for use in lifting or positioning
houses and / or other building structures. The jack complies with applicable ASME/ANSI
Standards. For air actuated use, ensure that your air source can dedicate is recommended.
SPECIFICATION
Model: CT0970
Capacity: 20 Ton
Min height: 260 mm
Max height: 510 mm
Lifting height: 170 mm
Adjust height: 80 mm
Working pressure:120-180psi
BEFORE USE
1. Verify that the product and the application are compatible, if in doubt call seller’s telephone.
2. Before using this product, read the owner’s manual completely and familiarize yourself
thoroughly with the product and the hazards associated with its improper use.
3. Open the release valve (counter – clockwise no more
than 2 full turns).
4. With ram fully retracted, locate and remove the oil
filler plug. Insert the handle into the handle sleeve,
then pump 6 to 8 strokes. This will help release any
pressurized air whicj may be trapped within the
reservior. Ensure the oil level is just below the oil
filler plug hole. Re-install the oil filler plug.
5. Pour a teaspoon of good quality, air tool lubricant
Into the air supply inlet of the lift control valve.
Connect to air supply and operate for 3 seconds to
evenly distribute lubricant.
6. Check to ensure that jack rolls freely(if so equipped) and that the pump operates smoothly
before putting into service. Replace worn or damaged parts and assemblies with seller’s only.
7. This product is fitted to accept the popular 1/4” NPT air nipple. When installing 1/4” NPT
nipple of your choice, ensure that thread tape or compound is used when servicing
connections.
8. Inspect before each use. Do not use if bent, broken or cracked components are noted.
2