background image

Important safety information    

en

3

(

Important safety 

information

Important safety information

:

Warning – Danger of suffocation! 

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

:

Warning – Danger of death! 

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room 

if the appliance is being operated in exhaust 

air mode at the same time as room air-

dependent heat-producing appliance is being 

operated.

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or 

water heaters) obtain combustion air from the 

room in which they are installed and discharge 

the exhaust gases into the open air through an 

exhaust gas system (e.g. a chimney).

In combination with an activated vapour 

extractor hood, room air is extracted from the 

kitchen and neighbouring rooms - a partial 

vacuum is produced if not enough fresh air is 

supplied. Toxic gases from the chimney or the 

extraction shaft are sucked back into the living 

space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning – Risk of fire! 

Grease deposits in the grease filter may 

catch fire.

Clean the grease filter at least every 

2 months. 

Never operate the appliance without the 

grease filter.

Risk of fire! 

Grease deposits in the grease filter may 

catch fire. Never work with naked flames 

close to the appliance (e.g. flambéing). Do 

not install the appliance near a heat-

producing appliance for solid fuel (e.g. 

wood or coal) unless a closed, non-

removable cover is available. There must 

be no flying sparks.

Risk of fire! 

Hot oil and fat can ignite very quickly. Never 

leave hot fat or oil unattended. Never use 

water to put out burning oil or fat. Switch off 

the hotplate. Extinguish flames carefully 

using a lid, fire blanket or something similar. 

Risk of fire! 

When gas burners are in operation without 

any cookware placed on them, they can 

build up a lot of heat. A ventilation 

appliance installed above the cooker may 

become damaged or catch fire. Only 

operate the gas burners with cookware on 

them.

Risk of fire! 

Operating several gas burners at the same 

time gives rise to a great deal of heat. A 

ventilation appliance installed above the 

cooker may become damaged or catch fire. 

Never operate two gas burners 

simultaneously on the highest flame for 

longer than 15 minutes. One large burner of 

more than 5 kW (wok) is equivalent to the 

power of two gas burners.

:

Warning – Risk of burns! 

The accessible parts become very hot when in 

operation. Never touch hot parts. Keep 

children at a safe distance.

Содержание N 70 D46ML54N0B

Страница 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Страница 2: ...ation This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufactur...

Страница 3: ...se consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible...

Страница 4: ...appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaner...

Страница 5: ...mentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilat...

Страница 6: ...the AirFresh function press the button Noise reduction function The noise reduction function reduces the fan noise Switching on the appliance Press the 4 button The function is possible in all fan se...

Страница 7: ...sensor setting the fan automatically switches to another fan setting Default sensitivity setting Lowest sensitivity setting Highest sensitivity setting If the sensor control responds too quickly or t...

Страница 8: ...arning Risk of burns The appliance will become hot during operation especially near the bulbs Allow the appliance to cool down before cleaning Warning Risk of electric shock Penetrating moisture may r...

Страница 9: ...be wedged in Removing metal grease filter 1 Open the lock and fold down the metal grease filter While doing this place your other hand under the metal grease filter 2 Take the metal grease filter out...

Страница 10: ...advice The rating plate with these numbers can be found inside the appliance remove the metal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone n...

Страница 11: ...set Z54TS02X0 Z54TC02X0 Basic equipment CleanAir air recirculation module Easy change filter for CleanAir air recirculation module Z54TR60X0 Z54TR00X0 Lowering frame Appliance width 60 cm Z54TL60X0 Lo...

Страница 12: ...t individual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special accessories...

Страница 13: ...and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room air is extracted from the kitchen and neighbou...

Страница 14: ...r of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information GeneralinformationExhaust air mode Warning Risk of death Risk of...

Страница 15: ...nstalling a residual current circuit breaker RCCB in the appliance s power supply circuit Preparing the units The fitted unit must be level and have sufficient load bearing capacity The max weight of...

Страница 16: ...to the body on the left and right 3 Remove the tabs from the bottom of the mounting pieces Preparing the appliance A handle strip must be screwed to the filter pull out This handle strip can be one t...

Страница 17: ...hob with a piece of polystyrene from the packaging 1 Use a flat blade screwdriver to push in the fastening bolt and turn it 90 until it locks into place 2 Push in the fastening bolt gently with your...

Страница 18: ...ilter pull out can be changed Spacers are included with these appliances in order to position the appliance s handle strip flush with the fitted unit 1 Pull the filter pull out towards you 2 Shorten t...

Страница 19: ...Installation en 19...

Страница 20: ...9001058693 9001058693 980402 en...

Отзывы: