Control panel model 2

Control panel

Setting the fan

Switching on

Pull out the filter pull-out and press the 

#

 button. The 

fan starts at setting 

ƒ

.

Press the + or - button to change the fan strength.

Switching off

Press the 

#

 button. Slide the filter pull-out in.

Intensive setting

You can use the intensive setting if there is a large 

build-up of odours and fumes/vapours.
Press the + button when the fan is at setting 

.

The intensive setting

 ˜‚

 is activated. Pressing the + 

button again activates the intensive setting 

 ˜ƒ

.

After approx. six minutes, the electronics automatically 

reduce the fan to a lower setting . If you want to end the 

intensive setting before the preset time expires, press 

the - button until the required fan setting is reached.

Automatic mode

Switching on

Press the 

#

 button.

The fan starts at setting 

ƒ

.

Press the 

 button.

The optimum fan setting 

‘‚

‘ƒ

 or 

‘„

 is 

automatically set via a sensor.

Switching off

Press the 

 button or the 

#

 button to switch off 

automatic mode.
The fan switches off automatically if the sensor no 

longer detects a change in the air quality of the room.
Automatic mode can run for a maximum of four hours.

Sensor control

In automatic mode, a sensor in the extractor hood 

detects the intensity of the cooking and roasting fumes. 

Depending on the sensor setting, the fan automatically 

switches to another fan setting.
Default sensitivity setting:  

Lowest sensitivity setting:  

Highest sensitivity setting:  

Š

If the sensor control responds too quickly or too slowly, 

it can be changed accordingly:

1.

When the fan is switched off, press and hold the 

 

symbol for approx. four seconds. The setting is 

displayed.

2.

The sensor control setting is changed by pressing 

the + or – button.

3.

To confirm the entry, press and hold the 

 symbol 

for approximately four seconds.

Fan run-on time

Press the - button until 

 appears, or slide in the filter 

pull-out.
After approx. 10 minutes, the fan switches off 

automatically.

AirFresh function

Press the - button until 

3

 appears. The fan runs for 

approx. five minutes per hour.
If you want to end the AirFresh function, press the 

#

 

button.

Noise reduction function

The noise reduction function reduces the fan noise.

Switching on the appliance

Press the 

4

 button. 

The function is possible in all fan settings, except in fan 

setting 

. It also remains active after the fan is switched 

off.

Switching off the appliance

Press the 

4

 button. 

Lighting

The lighting can be switched on and off independently 

of the fan.
Press the 

A

 button.

Setting the brightness

Press and hold the 

A

 button until the desired 

brightness is reached.

Explanation

#

Fan on/off

4

Noise reduction

 -

Reduce the fan settings/fan run-on time/interval ventilation

 +

Increase the fan settings/intensive mode 1, 2

Automatic function

A

Light on/off/dimming

IUHVK

YRO

YRO

Содержание N 70 D46ML54N0B

Страница 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Страница 2: ...ation This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufactur...

Страница 3: ...se consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible...

Страница 4: ...appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaner...

Страница 5: ...mentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilat...

Страница 6: ...the AirFresh function press the button Noise reduction function The noise reduction function reduces the fan noise Switching on the appliance Press the 4 button The function is possible in all fan se...

Страница 7: ...sensor setting the fan automatically switches to another fan setting Default sensitivity setting Lowest sensitivity setting Highest sensitivity setting If the sensor control responds too quickly or t...

Страница 8: ...arning Risk of burns The appliance will become hot during operation especially near the bulbs Allow the appliance to cool down before cleaning Warning Risk of electric shock Penetrating moisture may r...

Страница 9: ...be wedged in Removing metal grease filter 1 Open the lock and fold down the metal grease filter While doing this place your other hand under the metal grease filter 2 Take the metal grease filter out...

Страница 10: ...advice The rating plate with these numbers can be found inside the appliance remove the metal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone n...

Страница 11: ...set Z54TS02X0 Z54TC02X0 Basic equipment CleanAir air recirculation module Easy change filter for CleanAir air recirculation module Z54TR60X0 Z54TR00X0 Lowering frame Appliance width 60 cm Z54TL60X0 Lo...

Страница 12: ...t individual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special accessories...

Страница 13: ...and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room air is extracted from the kitchen and neighbou...

Страница 14: ...r of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information GeneralinformationExhaust air mode Warning Risk of death Risk of...

Страница 15: ...nstalling a residual current circuit breaker RCCB in the appliance s power supply circuit Preparing the units The fitted unit must be level and have sufficient load bearing capacity The max weight of...

Страница 16: ...to the body on the left and right 3 Remove the tabs from the bottom of the mounting pieces Preparing the appliance A handle strip must be screwed to the filter pull out This handle strip can be one t...

Страница 17: ...hob with a piece of polystyrene from the packaging 1 Use a flat blade screwdriver to push in the fastening bolt and turn it 90 until it locks into place 2 Push in the fastening bolt gently with your...

Страница 18: ...ilter pull out can be changed Spacers are included with these appliances in order to position the appliance s handle strip flush with the fitted unit 1 Pull the filter pull out towards you 2 Shorten t...

Страница 19: ...Installation en 19...

Страница 20: ...9001058693 9001058693 980402 en...

Отзывы: