34
Mains cable
Depending on the type of power supply, a mains
cable complying with the following specifications
should be used.
For a connection with 400V3N~
(models designed to be connected as per
DIAGRAM C, but which are reversed by the fitter as
per DIAGRAM A):
Use a 5-pin cable, type H05RR-F/H05RN-F
(cable dimensions: 5 x 2.5 mm
2
).
For a connection with 230V3~
(models designed to be connected as per
DIAGRAM C, but which are reversed by the fitter as
per DIAGRAM B):
Use a 4-pin cable, type H05RR-F/H05RN-F
(cable dimensions: 4 x 4 mm
2
).
For a connection with 230V1N~ (models
which are connected in accordance with
DIAGRAM C):
Use a 3-pin cable, type H05RR-F/H05RN-F
(cable dimensions: 3 x 4 mm
2
).
At the end of the mains cable connected to the
appliance, the yellow/green wire must be at least
20 mm longer than the other wires.