background image

en

    Customer service

16

4

Customer service

Customer service

When calling us, please quote the product number

(E no.) and the production number (FD no.) so that we 

can provide you with the correct advice. These numbers 

can be found on the rating plate on the top of the 

appliance.

You can make a note of the numbers of your appliance 

and the telephone number of the after-sales service in 

the space below to save time should it be required.

Please be aware that a visit by an after-sales engineer 

will be charged if a problem turns out to be the result of 

operator error, even during the warranty period.
Please find the contact data of all countries in the 

enclosed customer service list.

To book an engineer visit and product advice

Rely on the professionalism of the manufacturer. You 

can therefore be sure that the repair is carried out by 

trained service technicians who carry original spare 

parts for your appliances.

Accessories

(not included in the scope of delivery)

Note: 

These instructions apply to several appliance 

models. It may be the case that an optional accessory 

that is listed does not apply for your appliance.

Note: 

Observe the installation instructions in the 

accessory.

--------

E no.

FD no.

After-sales service

O

GB

0344 892 8989 

Calls charged at local or mobile rate.

IE

01450 2655 

0.03 € per minute at peak. 

Off peak 0.0088 € per minute.

=1U

)'

(1U

7\SH

Accessories

Order number

Starter set for air-recirculation mode (flat hood 

with chimney)
Easy-change filter for starter set

Z51AFU0X0

Z51AFA0X0

Starter set for air-recirculation mode (flat hood 

without chimney)
Easy-change filter for starter set

Z51AFT0X0

Z51AFA0X0

Starter set for air-recirculation mode (angled hood 

with chimney)
Easy-change filter for starter set

Z51AIU0X0

Z51AIA0X0

Starter set for air-recirculation mode (angled hood 

without chimney)
Easy-change filter for starter set

Z51AIT0X0

Z51AIA0X0

Starter set for air-recirculation mode with filter 

that can be regenerated (flat hood with chimney)

Z51AFS0X0

Starter set for air-recirculation mode with filter 

that can be regenerated (angled hood with chim-

ney)

Z51AIS0X0

Starter set for air-recirculation mode with filter 

that can be regenerated (flat hood without chim-

ney)

Z51AFR0X0

Starter set for air-recirculation mode with filter 

that can be regenerated (angled hood without 

chimney)

Z51AIR0X0

CleanAir air-recirculation module
Easy-change filter for CleanAir air-recirculation 

module (cannot be regenerated)

Z51AXC1N6
Z53XXB1X6

Easy-change filter for CleanAir air-recirculation 

module (can be regenerated)

Z50XXP0X0

Содержание EXTRACTOR HOOD

Страница 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Страница 2: ......

Страница 3: ...ance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable...

Страница 4: ...by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you U...

Страница 5: ...electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on the appliance wh...

Страница 6: ...onmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventil...

Страница 7: ...n is switched off Touch the Q symbol Switching off Touch the Q symbol AirFresh function Switching on Touch the 3 symbol 3 will be shown on the display panel The fan runs for approximately 5 minutes pe...

Страница 8: ...nction Saturation display If the metal grease filters or activated charcoal filter are is saturated the corresponding symbols will flash once the appliance has been switched off Metal grease filter Ac...

Страница 9: ...he 9 symbol This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol will light up o...

Страница 10: ...hold the 6 symbol until the required brightness is reached Saturation display If the metal grease filters or activated charcoal filter are is saturated the corresponding symbols will flash once the a...

Страница 11: ...ched on and is in search mode To do this refer to the section entitled Connecting to the extractor hood in the instruction manual for your hob Connecting directly Notes Before connecting the appliance...

Страница 12: ...ed on during the connection process You can cancel the process at any time by pressing the symbol To connect the extractor hood to your home network the extractor hood must be switched on 1 Press and...

Страница 13: ...reset the connections you have saved on your home network and on Home Connect at any time Press and hold the and symbols at the same time until an audible signal sounds When the audible signal is swi...

Страница 14: ...th the cleaning products Removing metal grease filter 1 Open the glass front slowly and fully Hold the glass front in the centre when doing so gripping it firmly 2 Open the lock and swing down the met...

Страница 15: ...his take hold of the metal grease filter from underneath with your other hand Note Make sure that the metal grease filter is positioned correctly 2 If the metal grease filter has not been inserted cor...

Страница 16: ...s in the accessory E no FD no After sales serviceO GB 0344 892 8989 Calls charged at local or mobile rate IE 01450 2655 0 03 per minute at peak Off peak 0 0088 per minute 1U 1U 7 SH Accessories Order...

Страница 17: ...or hood is to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air rec...

Страница 18: ...ith the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the...

Страница 19: ...t are drawn back in If installing a ventilation system in a room with a heat producing appliance connected to a chimney flue the electricity supply to the hood must be equipped with a suitable safety...

Страница 20: ...l connection Warning Risk of electric shock Components inside the appliance may have sharp edges These may damage the connecting cable Do not kink or pinch the connecting cable during installation The...

Страница 21: ...r hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor h...

Страница 22: ...out a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP...

Страница 23: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of...

Страница 24: ...9001227077 9001227077 990901 en...

Отзывы: