6

Filters and maintenance

2.

Clean the filters.

3.

Insert the clean filters back into the
hood.

3.

Engage the lug at the front.

4.

Insert the metal grease filters (see
"Removing and inserting the metal 
grease filters").

Replacing the activated carbon filter:

During normal operation (1 to 2 hours
per day) the activated carbon filters
should be replaced approximately 1 x
year.

A replacement filter can be obtained
from any authorized dealer (see optional 
accessories).

Use original filters only.

By doing so you will obtain maximum
performance from your extractor hood.

Disposing of the old activated carbon 
filter:

There are no pollutants in the activated
carbon filters. They can therefore be 
disposed of as part of your normal
domestic refuse.

Installation and removal:

Warning: 

The halogen bulbs must be 

switched off and cool.

1.

Remove the metal-mesh filters
(see "Removing and inserting the metal-
mesh grease filters").

2.

Insert the activated carbon filter.

Activated carbon filter:

For neutralizing odours in recirculating
mode.

Caution:

As the filter becomes more and more 
saturated with grease, there is an increased
risk of fire and the function of the extractor
hood may be impaired.

Important:

Change the activated carbon filter promptly
to prevent the risk of fire from the 
accumulation of heat when deep-fat frying
or roasting.

Removing and inserting the metal grease
filters:

Warning: 

The halogen bulbs must be 

switched off and cool.

1.

Press the catch on the grease filters
inwards and fold the filters down.
At the same time take hold of the under-
side of the grease filters with your other
hand.

Содержание D86M35N0GB

Страница 1: ...Installation instructions and how to use and look after your built in cooker hoods D96M6N0 D99M6N0 NEFF UK Ltd...

Страница 2: ...2 mind 650 mind 550 Abb 1 ELECTRO Fig 1 GAZ...

Страница 3: ...stion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the...

Страница 4: ...to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified per...

Страница 5: ...ance Grease filters Metal filters are used to trap the greasy element of the vapours that develop during cooking The filter mats are made from non combustible metal Caution As the filter becomes more...

Страница 6: ...as part of your normal domestic refuse Installation and removal Warning The halogen bulbs must be switched off and cool 1 Remove the metal mesh filters see Removing and inserting the metal mesh greas...

Страница 7: ...hlorine Clean the extractor hood with a hot soap solution or a mild window cleaner Do not scrape off dried on dirt but wipe off with a damp cloth When cleaning the grease filters remove grease deposit...

Страница 8: ...iance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment b...

Страница 9: ...the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air ca...

Страница 10: ...nternal cross section that equates to that of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exha...

Страница 11: ...onnector If it is necessary to wire the extractor hood directly into the mains The extractor hood should only be connected to the electricity supply by a properly qualified electrician A separator mus...

Страница 12: ...e hob and the extractor hood is maintained 550 mm for an electric hob and 650 mm for a gas hob The bottom edge of the template equates to the lower edge of the extractor hood 4 Drill 4 x l 8 mm holes...

Страница 13: ...anelling together slots in the upper section must be pointing downwards and insert into the opening in the extractor hood Protect the cover panels from scratches for example by laying the template use...

Страница 14: ...14 Notes...

Страница 15: ...15 360732 Z 5116X5 1 2 3 4 5 6 2x 10x 2x...

Страница 16: ...9000 136 100 Printed in Germany 0206 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Отзывы: