The most effective method of removing

vapours produced during cooking is to:

Switch the ventilator ON

as soon as you begin cooking.

Switch the ventilator OFF

a few minutes after you have finished
cooking.

Operating procedure

Switching the fan ON

Press the 

+ button.

Setting the required fan speed:

Press the 

+ button.

The fan speed is increased by one step.

Press the 

– button.

The fan speed is reduced by one step.

Switching the fan OFF:

Press the 

0

button.

Or:

Keep pressing the 

button until the fan

switches off.

Intensive setting:

Maximum power is obtained at the 
intensive setting. It is only required for short
intervals.

Keep pressing the 

+

button until a 

ç

appears in the display.

If the intensive setting is not cancelled by
hand, the fan will automatically switch
back to step 

}

after 10 minutes.

Lighting:

The light can be switched on at any
time, even though the fan is switched off.

Fan OFF

Light
ON / OFF

0

Reduce fan
speed

Fan ON and
increase speed
Intensive setting

Display for fan setting

Filters and maintenance

Grease filters:

Metal filters are used to trap the greasy
element of the vapours that develop
during cooking.

The filter mats are made from non-
combustible metal.

Caution:

As the filter becomes more and more 
saturated with grease, not only does the
risk of it catching fire increase but the 
efficiency of the extractor hood can also be
adversely affected.

Important:

By cleaning the metal grease filters at
appropriate intervals, the possibility of them
catching fire as a result of a build-up of heat
such as occurs when deep-fat frying or 
roasting is taking place, is reduced.

Cleaning the metal grease filters:

In normal operation (1 to 2 hours daily),
the metal grease filter must be cleaned 
1 x a month.

The filters can be cleaned in a dish-
washer. It is however possible that they
will become slightly discoloured.

The filter must be placed loosely, and
NOT wedged, in the dishwasher.

Important:

Metal filters that are saturated with 
grease should not be washed together
with other dishes etc.

When cleaning the filters by hand, soak
them in hot soapy water first of all.
Do not use aggressive, acidic or caustic
cleaners.
Then brush the filters clean, rinse them
thoroughly and leave the water to drain off.

Содержание D86M35N0GB

Страница 1: ...Installation instructions and how to use and look after your built in cooker hoods D96M6N0 D99M6N0 NEFF UK Ltd...

Страница 2: ...2 mind 650 mind 550 Abb 1 ELECTRO Fig 1 GAZ...

Страница 3: ...stion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the...

Страница 4: ...to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified per...

Страница 5: ...ance Grease filters Metal filters are used to trap the greasy element of the vapours that develop during cooking The filter mats are made from non combustible metal Caution As the filter becomes more...

Страница 6: ...as part of your normal domestic refuse Installation and removal Warning The halogen bulbs must be switched off and cool 1 Remove the metal mesh filters see Removing and inserting the metal mesh greas...

Страница 7: ...hlorine Clean the extractor hood with a hot soap solution or a mild window cleaner Do not scrape off dried on dirt but wipe off with a damp cloth When cleaning the grease filters remove grease deposit...

Страница 8: ...iance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment b...

Страница 9: ...the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air ca...

Страница 10: ...nternal cross section that equates to that of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exha...

Страница 11: ...onnector If it is necessary to wire the extractor hood directly into the mains The extractor hood should only be connected to the electricity supply by a properly qualified electrician A separator mus...

Страница 12: ...e hob and the extractor hood is maintained 550 mm for an electric hob and 650 mm for a gas hob The bottom edge of the template equates to the lower edge of the extractor hood 4 Drill 4 x l 8 mm holes...

Страница 13: ...anelling together slots in the upper section must be pointing downwards and insert into the opening in the extractor hood Protect the cover panels from scratches for example by laying the template use...

Страница 14: ...14 Notes...

Страница 15: ...15 360732 Z 5116X5 1 2 3 4 5 6 2x 10x 2x...

Страница 16: ...9000 136 100 Printed in Germany 0206 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Отзывы: