background image

en 

Installation instructions

16

7.

Screw in the safety screw with the washer. 

Piping

Note: 

If you are using an aluminium pipe, smooth the

connection area beforehand.
We recommend the piping with an exhaust air pipe dia-

meter of 150 mm.

Establishing the exhaust air connection (exhaust

pipe, 150 mm diameter)

1.

Secure the exhaust pipe to the air pipe connector.

2.

Establish the connection to the exhaust air opening.

3.

Seal the joints.

Establishing the exhaust air connection (exhaust

pipe, 120 mm diameter)

1.

Secure the reducing connector to the air-pipe con-

nector.

2.

Secure the exhaust air pipe to the reducing con-

nector.

3.

Seal the joints.

Installing the flue duct

WARNING ‒ Risk of injury!

Components inside the appliance may have sharp

edges.

Wear protective gloves.

1.

Screw the retaining bracket for the flue duct to the

wall.

2.

To separate the flue ducts, remove the adhesive

tape or the flue duct from the protective packaging.

3.

Remove any protective foil from both flue ducts.

4.

Note: 

The slots on the flue duct should point down-

wards.
Push one flue duct section into the other.

5.

Note: 

To prevent scratches, lay soft towels over the

edges of the outer flue duct to protect the surface.
Place the flue duct sections on the appliance.

6.

Slide the inner flue duct section upwards, and at-

tach it to the left- and right-hand sides of the retain-

ing bracket. 

7.

Engage the flue duct section downwards. 

8.

Screw the flue duct section to the sides of the re-

taining bracket using two screws. 

9.

Use two screws to secure the outer flue duct sec-

tion to the appliance from below.

10.

Carefully remove the towels.

Содержание D64 Series

Страница 1: ...Extractor hood User manual and installation instructions D94 D64 D95 D65...

Страница 2: ...resulting dangers Do not let children play with the appliance Children must not perform cleaning or user maintenance unless they are at least 15 years old and are being supervised Keep children under...

Страница 3: ...isk of injury Components inside the appliance may have sharp edges Carefully clean the appliance interior Items placed on the appliance may fall off Do not place any objects on the appliance Changes t...

Страница 4: ...ang objects from them There is a risk of surface damage if you do not peel off the protective film Remove the protective film from all parts of the ap pliance before using for the first time Painted s...

Страница 5: ...non functioning smoke or ex haust gas flue you must obtain the consent of the heating engineer re sponsible If the exhaust air is conveyed through the external wall a tele scopic duct should be used...

Страница 6: ...Setting an operating mode Your appliance is set to air extraction mode by default Note When using it in circulating air mode you require additional accessories When using it in circulating air mode se...

Страница 7: ...ft cloth and glass cleaner Clean glass using a soft cloth and glass cleaner 3 Dry with a soft cloth 4 Apply a thin layer of the stainless steel cleaning product to stainless steel surfaces using a sof...

Страница 8: ...e of the metal grease filters Requirement The grease filters have been removed Removing the grease filter Page 7 1 Observe the information regarding the cleaning agents Cleaning products Page 7 2 Plac...

Страница 9: ...c trical and electronic appliances waste electrical and electronic equip ment WEEE The guideline determines the frame work for the return and recycling of used appliances as applicable throughout the...

Страница 10: ...shop or from our after sales service www neff international com Accessories Order number Clean Air Standard recir culation kit Z51DXI1X4 Clean Air Standard odour filter replacement Z51DXB1X4 Clean Ai...

Страница 11: ...tallation instructions en 11 13 3 Safety clearances Comply with the safety clearances for the appliance For Australia and New Zealand the minimum safety clearance above electrical cooktops must be 600...

Страница 12: ...the ap pliance is operated exclusively in circulat ing air mode Risk of poisoning from flue gases being drawn back in If an extractor hood with an open flued heat production source is installed the po...

Страница 13: ...nstallation must be prop erly installed Never equip the appliance with an external switching device e g a timer or remote control When the appliance is installed the mains plug of the power cord must...

Страница 14: ...pipe that is made of non combust ible material To prevent condensate from returning fit the ex haust pipe with a 1 gradient from the appliance 13 9 Instructions for the air extraction mode For air ex...

Страница 15: ...hole for the safety screw 3 Remove the appliance again 4 Drill an 8 mm diameter hole to a depth of 80 mm for the safety screw and press the wall plug flush into the wall 5 Remove the protective film f...

Страница 16: ...nside the appliance may have sharp edges Wear protective gloves 1 Screw the retaining bracket for the flue duct to the wall 2 To separate the flue ducts remove the adhesive tape or the flue duct from...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...er te GmbH Carl Wery Stra e 34 81739 M nchen GERMANY 9001673676 9001673676 030302 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Roa...

Отзывы: