Operating modes
Exhaust-air mode:
❑
The extractor-hood fan extracts the kit-
chen vapours and conveys them through
the grease filter into the atmosphere.
❑
The grease filter absorbs the solid
particles in the kitchen vapours.
❑
The kitchen is kept almost free of grease
and odours.
D
When the extractor hood is operated
in exhaust-air mode simultaneously with
a different burner which also makes use
of the same chimney
(such as gas, oil or
coal-fired heaters, continuous-flow heaters,
hot-water boilers) care must be taken to
ensure that there is an adequate supply
of fresh air
which will be needed by the
burner for combustion.
Safe operation is possible provided that the
underpressure in the room where the
burner is installed does not exceed 4 Pa
(0.04 mbar).
Lighting
Light / fan
switches
Filter grille
Chimney
panelling
Operating modes
This can be achieved if the combustion air
is able to flow through non-lockable
openings, e.g. in doors, windows and in
conjunction with an air supply/air-intake wall
box or by other technical procedures such
as reciprocal interlocking.
If the air intake is inadequate, there is a
risk of poisoning from combustion gases
which are drawn back into the room.
An air-intake/exhaust-air wall box by itself is
no guarantee that the limiting value will not
be exceeded.
Note: When assessing the overall
requirement, the combined ventilation
system for the entire household must be
taken into consideration. This rule does not
apply to the use of cooking appliances,
such as hobs and ovens.
Unrestricted operation is possible if the
extractor hood is used in recirculating mode
– with activated carbon filter.
Circulating-air mode:
❑
An activated carbon filter must be fitted
for this operating mode (see Filters and
maintenance).
The complete installation set and
replacement filters can be obtained
from
specialist
outlets.
The corresponding accessory numbers
can be found at the end of these
operating instructions.
❑
The extractor-hood fan extracts the
kitchen vapours which are purified in the
grease filter and activated carbon filter
and then conveyed back into the
kitchen.
❑
The grease filter absorbs the grease
particles in the kitchen vapours.
❑
The activated carbon filter binds the
odorous substances.
If no activated carbon filter is installed,
it is not possible to bind the odorous
substances in the cooking vapours.
Содержание D 9610
Страница 69: ...D 4 Pa 0 04 mbar 69...
Страница 70: ...70 FD T E 15 A...
Страница 71: ...71 0 2 3 8 10...
Страница 72: ...3 1 2 1 2 3 1 1 2 3 4 A 1 2 72...
Страница 73: ...73 4 40 Watt F 14 5 6 7 1 2 3...
Страница 74: ...74 TRGI 50 mm 650 mm 1 550 mm 1...
Страница 75: ...75 120 120 280 260 mind 45 684 1086 136 mind 400 mind 460 mind 60 500 600 900 D D 4 Pa 0 04 mbar...
Страница 76: ...76 100 mm 178 cm2 125 mm 113 cm2 125 mm 100 mm 125 mm 100 mm 3...
Страница 77: ...77 kg 15 0 60 cm 90 cm 17 0 17 5 19 5 1 30 m 3 mm LS...
Страница 78: ...78 30 178 347 36 5 400 mind 550 Elektro mind 650 Gas 216 ca 5mm 5 2 2 6 5 mm 7 1 2 3 550 mm 650 mm 4 4 2 8 mm...
Страница 79: ...08 4 09 10 13 2 1 2 3 14 79 11 12...
Страница 80: ...80 Notizen...
Страница 81: ...81 Notes...
Страница 82: ...82 204 536 361047 Z5117X5 90 cm Z5861N0 60 cm Z5860N0 1 2 3 4 5 6 2x 10x 2x 7...
Страница 83: ......