Nederman L-PAK Series Скачать руководство пользователя страница 18

L-PAK 150/250 Advanced

6.4 Standard Pilot Signal (PS) input

6.4.1 PS Input 2

Input 2, terminals 13 and 14 are for the standard pilot signal input. It is possible to set this input into 2 state
Standard or PSIFC mode.

Standard mode

Switch = Off: Filter cleaning by timer or manual cleaning is possible any time when PS is activated.

PSIFC mode

Switch = On: Filter cleaning by timer or manual cleaning is not possible when PS is activated.

Cleaning starts after PS = off.

ESC

OK

PSIFC-I2

1/1 

Switch = Off

Switch = off: Default setting.

6.4.2 PS Input 8

Default Advanced PSIFC (Pilot Signal Interlock Filter Cleaning)

L-PAK Advanced models are configured with Input 8 as a pilot signal input for the PSIFC filter cleaning process.

Input 8, terminals 11 and 17 act as pilot signal inputs and interlock the cleaning process. When this input is used
as a pilot signal input, filter cleaning cannot be activated until this PS input is deactivated. If this input activates
during a filter cleaning sequence, the filter sequence stops immediately and the unit establishes a vacuum.

Input 8 can be combined with input 2.

Example: Input 2 = (PSIFC-I2 = Off)

When PS Input 2 is used the filter cleaning can proceed any time but if Input 8 is activated the input will interlock
all filter cleaning attempts “Input 8 has the highest priority”.

6.5 Warning-Alarm output Q4

Potential free output Terminal X1:33-34.

When an alarm is activated, Output Q4 and White lamp button on the control box side flash with interval 1
second on / 1 second off.

Warning -Alarm Output Q4, switch with an interval 1 second on / 1 second off if one or more of the alarms listed
below are active:
• The fan temperature is over 125°C, see 

Section 5.3.1 Alarm! Fan Hi-Temp

.

• The motor is overheated, see 

Section 5.3.2 Alarm! Motor Protector Activated

.

• The compressed air level is low, see 

Section 5.3.3 Alarm! Low-Pressure CAS

.

Warning -Alarm Output Q4, switch with an interval 1 second on /3 seconds off if one or more of the warnings lis-
ted below are active:
• Warning Fan Hi-Temp, see 

Section 5.2.2 Warning! Fan Hi-Temp

.

6.6 Standby (Ready) indicator

The H1 lamp/Output DO1 acts as a Standby (unit ready) indicator. The H1 Lamp/DO1 is activated when the unit
is in Standby mode or the fan is running. The H1 lamp/Output DO1 is available on terminals X1:3 and X1:4 for re-
mote indication.

18

Содержание L-PAK Series

Страница 1: ...Instruction Manual PLC L PAK Series L PAK 150 250 Advanced 50 Hz 60 Hz Original instruction manual plc EN INSTRUCTION MANUAL PLC 2022 03 17 2130223 01...

Страница 2: ...L PAK 150 250 Advanced Trace back information Workspace Main version a1 Checked in 2022 03 17 Skribenta version 5 5 018...

Страница 3: ...ges 10 5 2 1 Time for service 10 5 2 2 Warning Fan Hi Temp 10 5 3 Alarm messages 10 5 3 1 Alarm Fan Hi Temp 11 5 3 2 Alarm Motor Protector Activated 11 5 3 3 Alarm Low Pressure CAS 11 6 PLC settings 1...

Страница 4: ...12 00m ESC OK Hi Vacuum Unit Running Time 05 33 Min DIRTm 00 00 s OTTmr 00 00 h ESC OK Hi Vacuum Unit IDLING Time To StandBy T 05 33m PS PS ESC OK Hi Vacuum Unit Running Time 05 33 Min DIRTm 10 00 s O...

Страница 5: ...L PAK 150 250 Advanced 5...

Страница 6: ...l 4 Unit Operation 4 1 Software with extended functional ity L PAK 150 250 Advanced comes with extended soft ware and a standard Logo PLC display that allows a technician to easily set parameters and...

Страница 7: ...Status messages The following status messages give information about what mode the unit is in or what routine service is being performed 5 1 1 L PAK Off Off mode The unit is in Off mode which is also...

Страница 8: ...o StandBy 05 33m Time to Standby The amount of time until the unit goes into Standby mode The default setting is 12 minutes See Section 6 2 4 SSR_Time 5 1 5 Filter Cleaning The unit is cleaning its fi...

Страница 9: ...tatus Report screen Press Escape and the up arrow at the same time to show the next Status Report screen Sn Software number Revision Language Starts The number of motor starts FLT M Prot Number of tim...

Страница 10: ...the filter cleaning valve is open to cool the fan When the Fan temperature is below 90 C the filter cleaning valve closes and the vacuum is reestablished again When the fan cooling function activates...

Страница 11: ...Fan Hi Temp Vacuum Unit Off Th 11 23 Reset OK Th The actual day and time when L Pak was stopped 5 3 2 Alarm Motor Protector Activated The motor is overheated Correct the problem and press OK to reset...

Страница 12: ...u 3 Press the down arrow to go to Program Press OK to confirm 4 Select Set Parameter Press OK to confirm 5 Use the up or down arrows to find the parameter Press OK to confirm 6 Use the left and right...

Страница 13: ...e the up or down arrows to set Time or Date Press OK to confirm Weekday is automatically set by the date 8 Press Escape 3 times to go to the time screen 9 Press the up arrow to exit NOTE There are sev...

Страница 14: ...signal disappeared 6 2 6 Weekly timer The weekly timer sets the unit to Stand By mode and Off Mode at preset times If the pilot signal PS is act ive and the Vacuum unit is in Standby mode the unit sta...

Страница 15: ..._ _ _ SS Default setting Saturday and Sunday On3 _ _ Default setting Time the unit set to Stand By on chosen D3 days Default setting is no preset time Off3 The time the unit is set to Off on chosen D3...

Страница 16: ...press the external standby button longer than 2 seconds and then release ESC OK OTTmr 1 1 T 02 00h Ta 00 00 T 02 00h Extra time before the unit goes into Off mode The default set ting is 2 hours Ta 00...

Страница 17: ...d Tpu 01 00s The default time for a complete cleaning cycle is 6 seconds Example 2 Cleaning pulses On 2 Tch 5 Tpu 1 On Tch Tpu 2 5 1 12s where Tch 05 00s and Tpu 01 00s The default time for a complete...

Страница 18: ...um Input 8 can be combined with input 2 Example Input 2 PSIFC I2 Off When PS Input 2 is used the filter cleaning can proceed any time but if Input 8 is activated the input will interlock all filter cl...

Страница 19: ...www nederman com...

Отзывы: