![Nederman FlexPAK 1000 DX Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/nederman/flexpak-1000-dx/flexpak-1000-dx_installation-and-service-manual_715611011.webp)
Nederman Insight Communication Cabinet
11
EN
1
Preface
Read the product documentation carefully before installation, use, and service of this
product. Replace documentation immediately if lost. Nederman reserves the right,
without previous notice, to modify and improve its products including documentation.
This product is designed to meet the requirements of relevant EU directives. To
maintain this status, all installation, maintenance, and repair is to be done by qualified
personnel using only Nederman original spare parts and accessories. Contact the nearest
authorized distributor or Nederman for advice on technical service and obtaining spare
parts. If there are any damaged or missing parts when the product is delivered, notify
the carrier and the local Nederman representative immediately.
This manual is supplemented by:
•
PLC Settings Manual for FlexPAK 800/1000 All Models.
2
Description
The Nederman Insight Communication Cabinet is an Insight system used together with
the FlexPak system. The gateway in the Communication Cabinet is connected to the
FlexPak control units. The gateway collects data from the control units and sends it to
Nederman Insight.
The customer can access the data by subscribing to Nederman Insight. This digital
subsciption service makes it possible to get feedback on the FlexPak units status
and prevent malfunctions. The feedback can help to optimize the system and unlock
potential energy savings. The subscription service also reminds when it is time for service
and/or maintenance of the FlexPak unit.
3
Safety
WARNING!
Risk of electric shock.
•
Always disconnect the main supply voltage before any electrical service.
•
Installation and dimensioning of power cable and choice of cable type has
to be done by an authorized electrician who can apply the local electricity
regulations to the installation.
4
Technical data
Environmental Specifications
IP Class
66
Operating temperature
-20° to +50°C
Storage temperature
-40° to +50°C
Relative humidity
10 to 95% non-condensing
Operating altitude
Up to maximum 2000m
Storage altitude
Up to maximum 3000m
Electrical Specifications
Supply Voltage:
Input L, N, PE 100-230VAC/120-230VDC
Frequency
50/60Hz
Input Current
1.21-0.67A / 0.57-0.29A
Input Power
68W