FilterBox Advanced III, Layout Dp Hose Advanced IEC / UL-CSA

17

20

Содержание FilterBox 12M

Страница 1: ...Installation and service manual Mobile Fume and Dust Extractors FilterBox OK 00000975 OK Original installation and service manual EN INSTALLATION AND SERVICE MANUAL 2020 05 06 144897 04 ...

Страница 2: ...FilterBox Trace back information Workspace Main version a6 Checked in 2020 05 06 Skribenta version 5 3 053 ...

Страница 3: ...Table of contents Figures 4 1 Preface 22 2 Troubleshooting 23 2 1 Download error log via USB 23 2 2 Update software via USB 23 2 3 Troubleshooting guide 23 2 4 Warnings 24 2 5 Errors 24 3 Electrical diagrams 25 3 ...

Страница 4: ...FilterBox Figures FilterBox Basic III 1Phase 110 120 220 240V IEC 1 4 ...

Страница 5: ...FilterBox FilterBox Basic III 3Phase 200 240V IEC 2 5 ...

Страница 6: ...FilterBox FilterBox Basic III 3Phase 380 420V IEC 3 6 ...

Страница 7: ...FilterBox FilterBox Basic III 1Phase 110 120 or 220 240V UL CSA 4 7 ...

Страница 8: ...FilterBox FilterBox Basic III 3Phase 208 240V UL CSA 5 8 ...

Страница 9: ...FilterBox FilterBox Basic III 3 Phase 440 480 575V UL CSA 6 9 ...

Страница 10: ...FilterBox FilterBox Advanced III 1Phase 110 120 220 240V IEC 7 10 ...

Страница 11: ...FilterBox FilterBox Advanced III 3Phase 200 240V IEC 8 11 ...

Страница 12: ...FilterBox FilterBox Advanced III 3Phase 380 420V IEC 9 12 ...

Страница 13: ...FilterBox FilterBox Advanced III 1Phase 110 120 or 220 240V UL CSA 10 13 ...

Страница 14: ...FilterBox FilterBox Advanced III 3Phase 208 240V UL CSA 11 14 ...

Страница 15: ...FilterBox FilterBox Advanced III 3Phase 440 480 575V UL CSA 12 15 ...

Страница 16: ...6 Fuse 0 5A Slow CC M DC Cleansing motor 24VDC 34W X1 X1 11 X1 12 8 10 11 M02 X1 10 X2 Remote Controll 1 24VAC 20W Fan On Off Blue Lamp On Off 1 2 Brown Black 3 Remote Controll 2 24VAC 20W Fan On Off Lamp On Off Brown Black Blue X1 3 3 6 7 5 4 Br Bk Bu X1 3 V1 9 P7 3 9 X1 3 Expansion Cleansing Contactor Rd Gr TC K1M 5 6 1 2 3 4 13 14 P5 2 P5 1 1 2 3 4 5 PGND Br Bu X3 X3 2 X3 1 Welding Current Sensor C...

Страница 17: ...156254 Solar 3281428 QM1 ALLEN BRADLEY Motor Overload Protector 1 5A 3P 193 EECB 2156253 Solar 3281427 QM1 ALLEN BRADLEY Motor Overload Protector 3 2 16 1P 193S EERB 2156255 Solar 3281451 QM2 ALLEN BRADLEY Transformator O load protector 0 1 0 16A 140M C2T A16 2162264 Solar 3118140 QM1 Reset Mode Auto Man 30s 20s 20s 15s 15s 10s 10s 30s Trip Class Default setting Auto 10s Brown Br Black Bk Blue Bu ...

Страница 18: ...FilterBox FilterBox Basic III Layout Power Cable Basic IEC UL CSA 15 18 ...

Страница 19: ...FilterBox FilterBox Basic III Layout Control Cable Basic IEC UL CSA 16 19 ...

Страница 20: ...FilterBox FilterBox Advanced III Layout Dp Hose Advanced IEC UL CSA 17 20 ...

Страница 21: ...FilterBox FilterBox Advanced III Wiring IEC UL CSA 18 21 ...

Страница 22: ...carefully before installation use and ser vice of this product Replace documentation immediately if lost Nederman reserves the right without previous notice to modify and improve its products including documentation This product is designed to meet the requirements of relevant EC directives To maintain this status all installa tion maintenance and repair is to be done by qualified personnel using ...

Страница 23: ...according to the motor nameplate Check if the rubber springs are in the correct posi tion Semi automatic or manual adjustment does not work Check that the springs are set in the up position Make sure the air cleansing is connected to com pressed air at a pressure of 5 8 bar The fan will not start Check the power connections Check the fuses Make sure the amps are set correctly according to the moto...

Страница 24: ...or and the main filter can rotate freely 2 5 Errors Table 2 3 Errors Error Solution Fan Motor overloaded Check that the motor can rotate freely Check the 3 phase connection and fuses External Fire detected Check the external fire alarm V Control transformer overheated Check the transformer voltage Check for a short circuit in the cable Overcurrent 10V DC circuits Check the transformer voltage Chec...

Страница 25: ...ox 3 Electrical diagrams See at the beginning of this manual NOTE The electrical diagrams are general and some external equipment e g Air cleaning valve V1 may not be installed depending on FilterBox model 25 ...

Страница 26: ...www nederman com ...