VP1103-200PM-00GB-Panel reader
Manual version 1.1 / Page
7
3.
Starting up operation
The Panel reader is pre-tuned and ready for use.
3.1.
Turn on the power
For an RS232 connection: Put the adaptor into an electric socket.
For CAN communication to a VPU: Turn on the Power supply VP2001.
3.2.
Checking the VP1103 Panel reader
3.2.1.
Checking the CAN connection to the VPU
Check the status of the Panel reader that is connected to a VPU in the Velos VPU program web
page
Maintenance > V-packs – Overview
.
3.2.2.
Checking the RS232 connection to a PC
Check the operation of the VP1103 Panel reader that is connected to a PC with the Hyper
Terminal program. Set the baud rate of the Hyper Terminal communication program to 9600.
The other settings are default.
The tags numbers that are identified by the Panel reader will be displayed in the screen
according to the ISO protocol 11784/11785.