background image

 

 

 

VP1007-200PM-00 ISO Reader I/O

 

Manual version 0.4 / Page 

4

   

 

4.2 Connections 

See the relevant equipment manual relating to where the VP1007 is to be installed.  
 

 

Figure : I/O of the VP1007. The input and output connections are shown above as an example. 

 
 

Details VP1007 inputs and outputs

 

 
Vin 

Power  

 

Minus  

RS232 / 485 

RxD / B-

Data receive 

 

TxD / A+

Data send 

 

- /   

Minus for RS232 / shield for RS485 

SYNC 

Synchronisation for HDX, AC (no plus or minus, cable must be twisted pair) 

 

See above 

I/O 1 .. 5 

Output max 400mA 

 

Output max 400mA / 1.7A input 

 

Minus for output (O) and minus input (I) 

 

Input 

ANTENNA 

Antenna 

F SYNC 

FI/FO 

Frequency synchronisation FI=in  FO=out 

 

Antenna minus (shield of coax cable) 

 
IMPORTANT : Use power supply with a fused output such as Velos VP2001, VP2002. 
 

Details Velos cable

 

 

oran

g

e

blue white 

blue 

black 

red 

orange w

h

ite 

Velos cable 

Switch

Light 

Velos cable OUT 
(same connection as IN) 

Red (+) 
Black (-) 
 
Blue (C

h)

 

Blue/white (C

l)

 

Shield 
 
Orange (Sync) 
Orange/white (Sync) 
Shield 

Power 

1,5 mm

2

 

 

Communication 

0,34 mm

2

 

Twisted pair shielded 
 

HF Synchronisation 

0,34 mm

2

 

Twisted pair shielded 

Part No. 7705310 

Содержание VP1007

Страница 1: ...Service manual For installation operation and service ISO Reader I O VP1007 April 2009 Manual version 0 4...

Страница 2: ...s publication conveys no license under any patent or other right nor does the publisher assume liability for any consequence of its use specifications and availability of goods mentioned in it are sub...

Страница 3: ...p 5 5 2 Address 5 5 3 Antenna 6 5 4 Software setup 6 6 Advanced 7 6 1 Testing inputs and outputs 7 6 2 Advanced antenna adjustment 7 6 3 Identification test options 8 7 Trouble shooting 9 8 Maintenanc...

Страница 4: ...VP1007 200PM 00 ISO Reader I O Manual version 0 4...

Страница 5: ...the VP1007 to operate inputs outputs and identification The VP1007 has the following main tasks Identification of tags ISO 134 2 kHz FDX HDX Two antenna connections available 1 active at the time Cont...

Страница 6: ...equency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likel...

Страница 7: ...stallation consits of the following steps 1 Mounting 2 Installation of all wiring connections 3 Power up 4 Set address when more then one VP1007 5 Check antenna adjustment green LED on 6 Check the con...

Страница 8: ...e twisted pair See above I O 1 5 Output max 400mA O Output max 400mA 1 7A input Minus for output O and minus input I I Input ANTENNA Antenna F SYNC FI FO Frequency synchronisation FI in FO out Antenna...

Страница 9: ...dress for example set address to 12 1 Short press on the button Ad will appear 2 Now hold the button till the display starts blinking dA will appear 3 Short press on the button SA will appear 4 Now ho...

Страница 10: ...f range Red on Antenna out of range Red blinking No antenna connected or low antenna signal All off Antenna switch off by the software 5 4 Software setup The software in the connected controller deter...

Страница 11: ...ton until i5 appears 4 Now hold the button until the display starts blinking Input 5 will be read 5 Activate the switch on and off If ok the display value will show zero and one 6 2 Advanced antenna a...

Страница 12: ...ing distance 6 If reading distance is ok leave the menu If not ok try another level 7 To leave the service menu and return to normal operation press the button until the display goes blank press about...

Страница 13: ...reset 03 Max I out high side 04 Max I out low side 05 CAN over voltage 06 CAN offset too high 07 08 09 Short circuit out5 minus 10 Short circuit out4 minus 11 Short circuit out3 minus 12 Short circui...

Страница 14: ...ng manufacturing the firmware is programmed and ready for use In case of an update it is possible to download new firmware thru the CAN bus In the Velos system the web browser interface of the VPU VP8...

Страница 15: ...ssible Detection distance Varies per antenna Synchronisation Synchronization according to ISO 11785 Environment Temperature Operating 10 50 C Storage 25 70 C Relative humidity 10 93 non condensing IP...

Страница 16: ...ay and push button Normally the display is off If there is no connection to the VPU the address is shown It is also possible some program states of a behavior component are shown during operation Acti...

Страница 17: ...9 0 Normally set to 0 Possible to set a lower value SIGNAL LEVEL FDX Shows signal level measured by the FDX receiver SIGNAL LEVEL HDX Shows signal level measured by the HDX receiver TEST IDENTIFICATI...

Страница 18: ...CAN bus connection Vin and Vout swapped Red Error plus and minus swapped overload Vo Green on Output power off No power Orange blinking Low power Red blinking Error plus and minus swapped COM Green on...

Страница 19: ...Appendix E RS485 connection RS 485 port of computer B A shield Power supply RS485 cable specifications computer to first VP1007 Wires min 0 34 mm2 twisted pair shielded Max length between computer an...

Страница 20: ...Reader I O Manual version 0 4 Page 16 Appendix F RS232 connections RS 232 port of computer RxD TxD GND RS232 cable specifications Shielded cable Wires min 0 34 mm2 Max length between Computer and VP1...

Страница 21: ......

Отзывы: