background image

PowerRouter • Solar Inverter • User Manual

6 Operation - advanced settings

17

EN

6.4

Check the system revision information

1.

Press 

yes

, and use up/down to select 

Service

.

2.

Press 

yes

, and use up/down to select 

Revision

.

3.

Press 

yes

, and use up/down to navigate through the parameters.

4.

When finished, press 

no

 several times to return to the to the status display.

6.5

Check the error history

1.

Press 

yes

, and use up/down to select 

Service

.

2.

Press 

yes

, and use up/down to select 

Errors

.

3.

Press 

yes

, and use up/down to navigate through the last ten error messages.

4.

When finished, press 

no

 several times to return to the to the status display.

6.6

Install wizard

 

i

You should not use the install wizard. The install wizard is used by qualified installation personel to change 
settings of the PowerRouter. This part of the menu is password protected, to avoid unintended changes to 
the system.

Parameter

Description

ID

Unique Part Serial number combination of the PowerRouter.

Platform

Firmware release number of the platform module.

DC/AC

Firmware release number of the grid module.

Solar

Firmware release number of the Solar module.

1

2

3

4

1

2

3

4

Содержание PowerRouter PR50S

Страница 1: ...User Manual PowerRouter Solar Inverter 5281555 B Date 010913...

Страница 2: ...PowerRouter Solar Inverter User Manual User Manual Original instructions Page 1 EN...

Страница 3: ...the status lines 8 4 5 Change the date 9 4 6 Change the time 9 4 7 Change the backlight setting 10 5 Operation check settings 11 5 1 Check the status of the system parameters 11 5 2 Check the status o...

Страница 4: ...Contents PowerRouter Solar Inverter User Manual 2 EN 6 6 Install wizard 17 7 Troubleshoot 18 7 1 Troubleshooting 18 7 2 Check the LED status 18...

Страница 5: ...uld result in injury CAUTION This symbol indicates a situation which if the instructions are not followed could result in damage to the equipment i This symbol indicates additional information to ensu...

Страница 6: ...not influence the functioning of the unit Damage due to moisture and or other environmental conditions i The installer dealer who installed the PowerRouter must report the defective PowerRouter system...

Страница 7: ...wer when exposed to light and can cause an electric shock energy or fire hazard The AC grid delivers electrical power 230 V 50 Hz This can cause an electrical shock and it can cause an energy or fire...

Страница 8: ...gned for indoor use It is designed for use with solar panels and connection to the grid For more information visit www PowerRouter com The PowerRouter is compliant with the following standards 2004 10...

Страница 9: ...utton to scroll through the menus selection list 4 Yes to select a sub menu or item No to return to the previous menu or to go back to the status display 5 On Off switch 4 2 Switch the PowerRouter on...

Страница 10: ...isplay clock date of the PowerRouter used for graphs on mypowerrouter com Day of the week Display day of the week Solar power Display Solar power instantaneous value Local power Display Local power in...

Страница 11: ...to change the day 7 Press yes to confirm the change or no to cancel When finished press no several times to return to the to the status display 4 6 Change the time 1 Press yes and use up down to sele...

Страница 12: ...down to select Settings 2 Press yes and use up down to select Display 3 Press yes and use up down to select Backlight 4 Press yes and use up down to select the desired setting 5 Press yes to confirm t...

Страница 13: ...lect Grid 3 Press yes and use up down to navigate through the parameters 4 When finished press no several times to return to the to the status display Parameter Description Ugrid Grid voltage xxx xx V...

Страница 14: ...urn to the to the status display i For an explanation of the parameters refer to the table in section 5 1 5 4 Check the status of the internet connection 1 Press yes and use up down to select Status 2...

Страница 15: ...yes and use up down to select Yield 4 Press yes and use up down to navigate through the parameters 5 When finished press no several times to return to the to the status display Parameter Description...

Страница 16: ...Today s amount of kWh fed to the grid Yesterday Yesterday s amount of kWh fed to the grid This week This week s amount of kWh fed to the grid Last week Last week s amount of kWh fed to the grid This...

Страница 17: ...select System 4 Press yes and use up down to navigate through the parameters 5 When finished press no several times to return to the to the status display Parameter Description Sensor 1 phase or 3 ph...

Страница 18: ...es to return to the to the status display i For an explanation of the parameters refer to the table in section 6 1 6 3 Check the internet connection parameters 1 Press yes and use up down to select Se...

Страница 19: ...rrors 3 Press yes and use up down to navigate through the last ten error messages 4 When finished press no several times to return to the to the status display 6 6 Install wizard i You should not use...

Страница 20: ...an error has occurred the LEDs will either be OFF or FLASHING as follows The LED can be on blinking or off The PowerRouter is receiving installing an update this process may last for 25 minutes The di...

Страница 21: ......

Страница 22: ...www PowerRouter com info PowerRouter com...

Отзывы: