NED
XCM6040SAT4 UME-xxxx-00
54
54
7.2 Noise on Image
Noises come out from
the beginning.
A
servomotor or a
magnetic valve is placed
near the camera.
The camera
has been used for 3 or
more years, or the ambient
temperature is higher than room
temperature.
There are some consumable parts
in the camera. Please contact us
for service.
The power supply
has been used for
3 or more years, or the ambient
temperature is higher than room
temperature.
Check the deterioration of the
power supply.
The camera, the camera cables and
the power source cable are in
swinging motion.
Check the deterioration of the
camera cables and the power
supply cable.
The camera can be out of order.
Please contact us for service.
Turning on a servomotor
or a magnetic valve
generates an electric
noise.
Prevent the noise
source from disturbing
the camera cables and
the power cable.
Yes
No
Yes
No
No
No
Yes
Yes
Yes
No
No
Yes
To next page
C