71
NED
XCM2080SAT4
/
XCM2040SAT4
UME-0006-04
8.6.2 Clock & Integration
Operating it in
『
Clock & Integration
』
tab.
Clock
:
Shows the camera internal clock frequency.
Note:
Read Only
Integration Time
:
Setting integration time. (Unit:
μs) When the trigger mode is Free Run, and Ext Edge
Dividing
/
Counter
:
First, choose a dividing clock from the drop-down-list-box.
Next, set a counter value with the slider, edit-box or the spin-button. Then, click
“Send” button.
Padding
:
Read Only
Scanrate -> Counter
automatic setting
:
The Counter value of Clock, Dividing, and Padding is calculated and set from the
present value when the scanning cycle to be set to the edit-box is input and it then
click on the scan rate->counter calculating button.
Note:
1) The calculating formula and the value at exposure time (Integration Time) are
displayed by the unit of μs.
2) The calculating formula and the value of PaddingTime are displayed by the unit of
μs.
3) The calculation value at scanning cycle (Scanrate) is displayed by the unit of μs.