23
NED
XCM2080SAT4
/
XCM2040SAT4
UME-0006-04
Table 3-3-1
Camera Link Connector (26-pin MDR Connector) pin assignments
CL1(Base/Medium Configuration) CL2(Medium Configuration)
No
NAME
No
NAME
I/O
No
NAME
No
NAME
I/O
1
Inner Shield
14
Inner Shield
-
1
Inner Shield
14
Inner Shield
-
2
X0 -
15
X0 +
OUT
2
Y0 -
15
Y0 +
OUT
3
X1 -
16
X1 +
OUT
3
Y1 -
16
Y1 +
OUT
4
X2 -
17
X2 +
OUT
4
Y2 -
17
Y2 +
OUT
5
Xclk -
18
Xclk+
OUT
5
Yclk -
18
Yclk +
OUT
6
X3 -
19
X3 +
OUT
6
Y3 -
19
Y3 +
OUT
7
SerTC +
20
SerTC -
IN
7
100
Ω
terminated
20
100
Ω
terminated
-
8
SerTFG -
21
OUT
8
Open
21
Open
-
9
CC1 -
22
CC1 +
IN
9
1
00
Ω
terminated
22
100
Ω
terminated
-
10
CC2 +
23
CC2 -
IN
10
100
Ω
terminated
23
100
Ω
terminated
-
11
CC3 -
24
CC3 +
IN
11
100
Ω
terminated
24
100
Ω
terminated
-
12
CC4 +
25
CC4 -
IN
12
100
Ω
terminated
25
100
Ω
terminated
-
13
Inner Shield
26
Inner Shield
-
13
Inner Shield
26
Inner Shield
-
Explanation of Signals
Inner Shield:
Shield cable (GND)
X0+, X0-
…X3+, X3-: Data output (Channel Link)
Xclk+, Xclk-, Yclk +, Yclk -: Clock output for above data output synchronization
(Channel Link)
Y0+, Y0-
…Y3+, Y3-: Data output (Channel Link)
SerTC+, SerTC- : Serial data input (LVDS)
, SerTFG-: Serial data output (LVDS)
CC1+, CC1- :
External synchronous signal input (LVDS)
CC2+, CC2-, CC3+, CC3-, CC4+, CC4-: Not in use (LVDS)
Camera Link compatible cable
3M: 14B26
–SZLB – xxx – 0LC by or equivalent
Notes:
1)
To avoid uncoupling of the cable connectors during power on, make sure to
clamp them with the locking screws.
2)
Do not unplug the cables while power is being supplied to the camera.