4.2.4.2 Setting Trigger Selector
Sets the Trigger.
・
Register name
Trigger Selector
・
VAL
Frame Active,
Exposure Start or
DummyFrameOutput
(Example)
Trigger Selector : Exposure Start
Figure 4-2-4-2 Trigger Selector
4.2.4.3 Setting Permission for using External Trigger
Sets the “Trigger Mode” of Register name to get permission for using the External
trigger. Select
“On” on the “Trigger Mode” if the External trigger is used.
・
Register name
Trigger Mode
・
VAL
Off / On
(Disable/Enable)
(Example)
Trigger Mode: On
Figure 4-2-4-3 Trigger Mode
*
Make sure that the trigger packet is supplied from the frame grabber board to the camera
before the
“Trigger Mode” is changed from “Off(Disable) to “On(Enable)” to get permission for
using the External trigger.
See 4.3 Examples of External trigger setting.