NED
RCDL4K8GE
UME-0111-01
36
LineIn2 /
LineIn3
<Off>
Encoder Reset
Activation
RW
Rising Edge /
Falling Edge /
Any Edge /
Level High /
Level Low
< Rising Edge >
Selects the Activation mode of the
Encoder Reset Source signal.
Encoder Reset
W
Software reset of encoder
(
Independent of ncoderResetSource
)
Encoder Value
RW
0
~
999999
<0>
Reads and writes Encoder counting
Encoder Value At Reset
R
0
~
4294967295
<0>
Reads the value of the of the position
counter of the selected Encoder when it
was reset by a signal or by an explicit
EncoderReset
command.
User Set Control
User Set Selector
RW
Default /
UserSet1
< UserSet1>
Default
:
factory settings
UserSet1
:
user settings 1
User Set Load
W
Loads the User Set specified by
UserSetSelector to the device and
makes it active.
User Set Save
W
Saves Current camera set values by
UserSetSelector in the memory.
User Set Default
RW
UserSet1
No need of Setting change
Transport Layer Control
Gev Current IP
Configration Persistent
IP
RW
True / False
<False>
True
:
ON
False
:
Off
Gev SCPS Packet Size
RW
512
~
9152
This GigE Vision specific feature
corresponds to
DeviceStreamChannelPacketSize and
should be kept in sync with it.
It specifies the stream packet size, in
bytes, to send on the selected channel
for a GVSP transmitter or specifies the
Содержание GiGE VISION RCDL4K8GE
Страница 17: ...NED UME 0111 01 RCDL4K8GE 17 The dimensions for camera are shown below Figure 2 2 1 Dimensions F Mount...
Страница 55: ...NED UME 0111 01 RCDL4K8GE 55 Figure 4 2 6 2 Color Transformation Value Selector...
Страница 91: ...NED UME 0111 01 RCDL4K8GE 91 Revision History Revision Number Date Changes 01 01 Oct 2020 Initial release...