background image

NECTA SPA TECHNICAL MANUAL 

SFERA

 “ 

Manual  

“ SFERA”  

 

 

17 / 

19

 

 
 
 

HACCP DIRECTIVE (EEC 93/43 and 96/3) 

Outline and instructions for use 

Notes: What is indicated by the EC Directive

 

 

Directives 

EEC 93/43 and 96/3

 concern the hygiene of food products and are based on the 

HACCP 

(

H

azard 

A

nalysis 

C

ritical 

C

ontrol 

P

oint). 

The purpose of this directive is to safeguard the consumer health, suggesting a series of actions to be taken by 
the vending company, aimed at checking, identifying and correcting any critical aspects in the foodstuff chain, 
from the purchase of products and machines to the dispensing of the product. 
The 

HACCP

 is a system used to analyse any potential risks in the manufacturing and distribution cycle of food 

product and to identify critical points where such risks can occur; the system also highlights the actions to be 
undertaken and the decisions to be made with regard to such critical points, as well as the implementation of 
checking and monitoring procedures.  
 

Therefore, each vending company must develop a Company Hygiene Self-control Manual according to the 

provisions of the directive - and if necessary use the information and recommendations formulated by some 

associations in the sector. The manual must contain a programming and checking schedule for the hygiene 

condition of each vending machine, and when a new machine is added this must be updated immediately.

 

 

Important notes

For a correct use of the machine, the directives must be fully applied.

 

The operator is responsible for 

correct operations on a vending machine 

 

HACCP Directives (EEC 93/43 and 96/3) 

Guidelines for correct application 

 

 

Ensure hygiene control with a special manual for correct hygiene practices. 

 

After cleaning, do not touch the surface of any elements that may come into contact with food. 

 

Wash your hands thoroughly, preferably using disinfectant, before starting any hygiene operations 

 

Use disposable sterile gloves 

 

Always use a clean cloth to wipe dry. 

 

Keep the work area tidy. 

 

Check that the product packages are intact and not damaged. 

 

Use products within the recommended time period (see expiry date on the package). 

 

Always use products from the warehouse according to the principle of “first-in first-out”. 

 

Consumables must be kept and transported separate from the cleaning and hygiene products. 

 

Drums and sectors must be cleaned regularly (see operating instructions). 

 

Do not fill internal zones of the machine with products to be loaded in a second occasion. 

 

The products that need to be kept at a refrigerated temperature must be transported to the location of the 
machine in containers that maintain the products at the ideal temperature or in containers that do not allow 
excessive temperature difference.

 

 

CLEANING THE MACHINE 

Carefully observe the following cleaning instructions! Considering that: 

The Snakky normally dispenses products with a long shelf life, but it can be enabled to dispense short shelf 

life products; in this case cleaning must be more frequent and stricter. 

In the following instructions, only the cleaning and hygiene operations for the 

FIRST 

case are described. 

 
Clean the machine, preferably at the end of the day or in the morning before the machine is used, and 

before loading the products to be sold. 

 

 

Fill in the checklist log for cleaning operations. 

 

When the display indicates an error message immediately check the trouble-shooting sheet. 

 

Use only recommended cleaning products approved for foodstuff, preferably liquid; do not use powder and 
abrasive products that could scratch plastic surfaces.

 

 

 

 

 

8  – HACCP DIRECTIVE

Содержание Sfera 6-32R / E

Страница 1: ...ECTA SPA TECHNICAL MANUAL SFERA Manual SFERA 1 19 SERVICE MANUAL SFERA BASIC TECHNICAL MANUAL THE CONTENTS OF THIS DOCUMENT ARE INTENDED FOR NECTA S AFTER SALES PERSONNEL AFTER SALES SERVICE Snack Foo...

Страница 2: ...d configuration Vending systems Power supply and Wiring Cooling unit Cabinet and Door Trouble shooting HACCP directive Use instructions Periodical cleaning and hygiene Daily Weekly Yearly Pages 3 4 5...

Страница 3: ...irect for five advertised selections NB2 without such code the machine is supplied with only the 12 button numeric keypad DESCRIPTION VARIABLES TRAYS Up to 6 max HEIGHT 0F TRAYS 96 mm min and up to 21...

Страница 4: ...e code is indicated on the side in any case there are many configurations options with simple and quick change operations Release spirals with different pitches are provided as indicated in the user m...

Страница 5: ...NECTA SPA TECHNICAL MANUAL SFERA Manual SFERA 5 19 Sfera 6 36R B Sfera 6 36R UK Sfera 6 32R E Sfera 6 36R D Version provided for Spain Version provided for Belgium Version provided for Germany...

Страница 6: ...th a 3 x 1 5 mm2 section 1 HO5 VV F 2 HO7 RN F In all configurations the cable is fitted with a SCHUKO plug permanently fixed to the cable NOTE In the event of replacement cables of exactly the same c...

Страница 7: ...Board Payment system connections NTC Probe Cooling unit control J12 RATIOMOTOR CONNECTIONS POWER SUPPLY UNIT CPU CENTRAL PROCESSING UNIT BOARD RS232 PORT PRINTER PROGRAMMER PC Phototransistor card Rec...

Страница 8: ...during the normal operation YELLOW LED It glows when 5 V DC is present in the board RED LED it glows when the software is reset program malfunction Minidip functions 1 4 REF 20 Coin mechanism setting...

Страница 9: ...NECTA SPA TECHNICAL MANUAL SFERA Manual SFERA 9 19 TRAY CONNECTION WIRING DIAGRAM CONNECTOR Detail of spiral control ratiomotor To connector J 12 CPU board 4 5 1 6 3 2...

Страница 10: ...FERA 10 19 POWER SUPPLY AND LIGHTING DIAGRAM 2 1 3 4 5 6 7 Wiring diagram of dispensing compartment slider lock device kit 1 2 Power supply EXE 3 4 Connector J14 24 V DC CPU board power supply 5 6 7 8...

Страница 11: ...o be able to dispense 20 to 76 mm wide products In addition the spirals can be right or left hand to be used in double compartment configuration with double spiral The ratiomotor is fitted with a mini...

Страница 12: ...ile the lamps and the cooling unit are controlled by means of special relay cards at the grid voltage The power supply unit is housed in a removable galvanised steel metal box for greater accessibilit...

Страница 13: ...condenser cooling from the lower part of the base through a filter that removes the dust such filter is accessible and easy to remove for cleaning FIG 2 The cooling air is expelled from the front sid...

Страница 14: ...by means of a single lock located inside the sliding compartment on the right A sliding compartment is located on the front right side with the user interface integrated on its front panel the CPU bo...

Страница 15: ...nge the operating default values The machine will continue working but some parameters could have been changed with consequences to the general functioning the RAM needs to be initialised as soon as p...

Страница 16: ...otected against short circuits with two line fuses one on each phase with fuses on the secondary winding and on CPU board power supply see wiring diagram Check that the fuses are intact and if necessa...

Страница 17: ...hygiene practices After cleaning do not touch the surface of any elements that may come into contact with food Wash your hands thoroughly preferably using disinfectant before starting any hygiene ope...

Страница 18: ...cabinet with a cloth dampened with a chlorine based detergent Check that there are no small insects Open the door and disconnect the machine form the power supply FIG 1 Clean the outside and inside of...

Страница 19: ...ed detergents Completely remove the cooling unit FIG 3 thoroughly clean the internal base and make hygienic Remove all the dust from the fans and cooling unit condenser FIG 4 Clean and make hygienic t...

Отзывы: