Program 40 to 92
Xen Topaz Programming Manual 303
P
ROGRAM
80: B
ASIC
H
ARDWARE
S
ETUP
FOR
T
RUNK
81-01: A
NALOGUE
T
RUNK
I
NITIAL
D
ATA
S
ETUP
Description
Use
Program 81-01 : Analogue Trunk Initial Data Setup
to define the various basic timers for the Trunk
Interface of 308M/308ME cards.
Input Data
IN
SA
SB
Prog. No.
Item
Input Data
Default
81-01-01
Companding method type
0 : µ-law
1 : A-law
1(A-law)
81-01-02
Loop Current Detection Time
1-255(8-2040ms)
75(600ms)
81-01-03
Clear Signal (Open Loop) Detection Time
1-255(8-2040ms) 37(296ms)
81-01-04
Ring Signal Detection Min. Time
1-255(8-2040ms) 13(104ms)
81-01-05
Single Ringing Detection Min. Time
0-255(0,8-2040ms) 82(656ms)
81-01-06
Double Ringing Detection Min. Off Time
0-255 (0,8-2040mS)
13 (104ms)
81-01-07
Double Ringing Detection Max. Off Time
0-255 (0,8-2040mS)
75 (600ms)
81-01-08
Ringing Signal Not Detection Minimum
1-255 (8-2040mS)
88 (704ms)
81-01-09
Time Ringing Signal Stop Detection Time
1-255 (64-16320mS)
38(304ms)
81-01-10
Continuous Ringing Minimum Time
0-255 (0,8-2040mS)
25(200ms)
81-01-11
Continuous Ringing Maximum Time
0-255 (0,8-2040mS)
88(704ms)
81-01-12
AC Impedance Timer
1-255 (64-16320mS)
4 (256ms)
81-01-13
Grounding
Time
1-255 (16-4080mS)
9 (144ms)
81-01-14
Flash (Hooking 1)
This sets the flash (Hooking 1) duration for
analogue trunk calls. See Program 14-02-04.
1-255 (16-4080mS)
6 (96ms)
81-01-15
Flash (Hooking 2)
This sets the flash (Hooking 2) duration for
analogue trunk calls. See Program 14-02-04.
1-255 (16-4080mS)
156(2496ms)
81-01-16
Pause
Time
1-255(64-16320mS) 47(3008ms)
81-01-17
PFT Idle Detection Time
1-255(64-16320mS) 47(3008ms)
81-01-18
Grounding
Start
Time
1-255 (8-2040mS)
6 (48ms)
81-01-19
Grounding Start Give-up Time
1-255 (64-16320mS)
47 (3008ms)
81-01-20
Loop Reverse Detect Min. Time
1-255 (8-2040mS)
13 (104ms)
81-01-21
Loop Reverse Detect Max. Time
1-255 (8-2040mS)
107 (856ms)
81-01-22
Loop Disconnect Detect Min. Time
1-255 (8-2040mS)
63(504ms)
81-01-23
Loop Disconnect Detect Max. Time
1-255 (8-2040mS)
87(696ms)
81-01-24
On Hook Normal Detect Time
1-255 (8-2040mS)
3(24ms)
81-01-25
On Hook Reverse Detect Time
1-255 (8-2040mS)
2 (16ms)
81-01-26
On Hook Disconnect Detect Time
1-255 (16-4080mS)
188 (3008ms)
Содержание Xen Topaz
Страница 1: ...Version 1 1 October 2004 Xen Topaz System Programming Manual ...
Страница 8: ...This page left intentionally blank ...
Страница 59: ...Xen Topaz Programming Manual 52 Program 10 to 11 This page left intentionally blank ...
Страница 115: ...Program 12 to 15 Xen Topaz Programming Manual 108 This page left intentionally blank ...
Страница 343: ...Program 40 to 92 Xen Topaz Programming Manual 336 This page left intentionally blank ...