Program 21 to 25
Xen Topaz Programming Manual 212
P
ROGRAM
25: DID/DISA S
ETUP
25-07: S
YSTEM
T
IMER
FOR
DID/DISA/VRS
Description
Use
Program 25-07 : System Timers for DID/DISA/VRS
to set the value for the system timers which af-
fect DID and DISA. Refer to the following chart for a description of each option, its range and default set-
ting.
Input Data
IN
SA
SB
Prog. No.
Item
Input Data
Default
Related
Program
25-07-01
DISA/VRS Dial Tone Time
After answering a DISA/VRS trunk, the system waits this
interval for the caller to dial the first digit of the DISA pass-
word. If the caller fails to dial within this interval, the system
drops the call
0-64800(sec)
0 = Off
10
22-02
25-04
25-07-02
DID/DISA No Answer Time
A DISA caller can ring an extension for this interval
before the system sets the call as a Ring No Answer.
After this interval expires, the call follows the programmed
Ring No Answer routing (set in Program
25-03 and 25-04).
0-64800(sec) 10 25-04
25-07-03
Disconnect after DID/DISA re-transfer to IRG
0-64800(sec)
60
25-07-04
Calling Time to Automatic answering Telephone set
0-64800(sec)
10
25-07-05
Duration time for Guidance Message by Automatic
answering telephone set
0-64800(sec) 10
25-07-06
Duration time for Guidance Message by ACI Talkie
0-64800(sec) 10
25-07-07
DISA Conversation Warning Tone Time
Determine the length of time a DISA caller can talk
before the Long Conversation tone is heard.
0-64800(sec) 1800
25-07-08
DISA Long Conversation Disconnect
This timer determines how long the system will wait
before disconnecting a call after the Long Conversation
tone is heard.
0-64800(sec) 30
25-07-09
DISA Internal Paging Time
This is the maximum length of an Internal Page placed by a
DISA caller. If the Page continues longer than this interval,
the system terminates the DISA call.
0-64800(sec) 30
25-07-10
DISA External Paging Time
This is the maximum length of an External Page placed by a
DISA caller. If the Page continues longer than this interval,
the system terminates the DISA call
0-64800(sec) 30
25-07-11
DID/DISA/VRS Answer Delay Timer
0-64800(sec)
0
25-07-12
-Not Used-
-
-
25-07-13
DID/DISA Busy Tone Interval
If a DISA caller dials a busy extension (and Program
25-04 = 0), the system plays busy tone for this interval
before disconnecting.
0-64800(sec) 5
25-07-14
Delayed DID Answer Timer
Assign the delay time from switching from a normal
incoming status to DID mode. If this time is set to ‘0’,
the call will switch to DID mode immediately.
0-64800(sec) 10 22-02
Содержание Xen Topaz
Страница 1: ...Version 1 1 October 2004 Xen Topaz System Programming Manual ...
Страница 8: ...This page left intentionally blank ...
Страница 59: ...Xen Topaz Programming Manual 52 Program 10 to 11 This page left intentionally blank ...
Страница 115: ...Program 12 to 15 Xen Topaz Programming Manual 108 This page left intentionally blank ...
Страница 343: ...Program 40 to 92 Xen Topaz Programming Manual 336 This page left intentionally blank ...