May 2003
Programming Manual
1 - 425
A
6
-324000
-642-
02 – Release 6.0
May 20
03
First Digit PBR
Release Timer
Selection
1-3-03
Specify the time that a receiver is
connected when a DTMF Single
Line Telephone user is dialling.
10 sec.
10 sec.
60 sec.
Hookflash Start Time
Selection
1-3-05
Specify a minimum hookflash
duration for a Single Line
Telephone to receive a second dial
tone.
40 ms.
290 ms.
790 ms.
Hookflash End Time
Selection
1-3-06
Specify a maximum duration from
a Single Line Telephone to receive
a second dial tone (HT = Hookflash
Start Time).
HST + 0 ms.
HST + 700
ms.
HST + 1500
ms.
Voice Mail DTMF
Delay Timer Selection
1-3-08
Specify the delay time before
DTMF tones are sent to the VMI
port.
0 sec.
1 sec.
8 sec.
Voice Mail Disconnect
Time Selection
1-3-09
Specify the sending time of a
disconnect signal that is sent to the
connected equipment.
.5 sec.
1.5 sec.
3.5 sec.
Voice Mail DTMF
Duration/Interdigit
Time Selection
1-3-10
Specify the DTMF duration/
interdigit time for voice mail.
60/70 ms.
110/80 ms.
810/190 ms.
Tandem Transfer
Automatic Disconnect
Timer Selection
1-4-00
Specify a maximum time before
automatic disconnect of a Trunk-
to-Trunk transfer occurs.
30 min.
1 hr.
3 hr.
Tandem Transfer
Automatic Disconnect
Timer Selection*
1-4-00
Specify a maximum time before
automatic disconnect of a Trunk-
to-Trunk transfer occurs.
000 min.
060 min.
999 min.
Automated Attendant
First Digit PBR
Release Timer
Selection
1-4-01
Specify the PBR connection time
to the Automated Attendant trunk
to receive the DTMF signal from
the calling party before
automatically disconnecting.
5 sec.
20 sec.
60 sec.
Automated Attendant
Transfer Delayed
Ringing Time
Selection
1-4-02
Specify the time for a No Answer at
the transferred station before the
Automated Attendant rings a
predetermined station.
10 sec.
No Limit
No Limit
Automated Attendant
No Answer
Disconnect Time
Selection
1-4-03
Determine how long the
Automated Attendant rings a
station before dropping the call.
1 min.
2 min.
4 min.
Automated Attendant
Answer Delay Time
Assignment
1-4-13
Assign the number of seconds
before the Automated Attendant
answers an incoming CO/PBX call
when there is no answer.
0 sec.
4 sec.
99 sec.
Table 1-6 Function Timer Chart (Continued)
Timer
Memory
Block
Definition
Timing Value
Minimum
Default
Maximum
*Software Version 2.xx or higher