12.2 Model Name Read
This command is used in order to read the Model Name.
1) The controller requests the monitor to read Model Name.
Header
Message
Check code
Delimiter
SOH-'0'-Monitor ID-
'0'-'A'-'0'-'6'
STX-'C'-'2'-'1'-'7'-ETX
BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get Model Name.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'6'(30h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'7' (43h, 32h, 31h, 37h): Model Name command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies the model name data to the controller.
Header
Message
Check code
Delimiter
SOH-'0'-'0'-Monitor ID-
'B'-N-N
STX-'C'-'3'-'1'-'7'-
Data(0) -Data(1)—----Data(n)-ETX
BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
N-N: Message length
Note.) The maximum data length that can be returned from the monitor at a time is
32bytes.
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Message
STX (02h): Start of Message
'C'-'3'-'1'-'7' (43h, 33h, 31h, 37h): Model Name reply Command
Data(0) -Data(1)----Data(n):Model name
Ø
The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Ex.) Foe example when receiving Model Name data 35h 30h 33h 34h 33h 30h 33h 33h
Step1: Model Name data is encoded character string.
Example:
35h 30h 33h 34h 33h 30h 33h 33h -> '5','0','3','4','3','0','3','3'
Step2: Decode pairs of ASCII characters to hexadecimal values.
Example:
'5','0','3','4','3','0','3','3' -> 50h 34h 30h 33h
Step3: Byte data represents the ASCII string data.
Example:
50h 34h 30h 33h -> "P403"
Result: Model Name is "P403".
Note: No null termination character is sent.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Содержание X754HB
Страница 6: ... 6 139 Please refer Controlling the LCD monitor via LAN control on User s manual ...
Страница 14: ... 14 139 4 4 Delimiter Packet delimiter code ASCII CR 0Dh Header Message Check code Delimiter ...
Страница 17: ... 17 139 18th byte ETX End of Message ASCII ETX 03h ...
Страница 51: ... 51 139 CR 0Dh End of packet ...
Страница 77: ... 77 139 Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...
Страница 89: ... 89 139 Delimiter CR 0Dh End of packet ...
Страница 98: ... 98 139 Delimiter CR 0Dh End of packet ...
Страница 102: ... 102 139 Delimiter CR 0Dh End of packet ...
Страница 104: ... 104 139 Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...
Страница 106: ... 106 139 Delimiter CR 0Dh End of packet ...
Страница 108: ... 108 139 Delimiter CR 0Dh End of packet ...
Страница 110: ... 110 139 Delimiter CR 0Dh End of packet ...
Страница 112: ... 112 139 Delimiter CR 0Dh End of packet ...
Страница 115: ... 115 139 Delimiter CR 0Dh End of packet ...
Страница 118: ... 118 139 Delimiter CR 0Dh End of packet ...
Страница 124: ... 124 139 Delimiter CR 0Dh End of packet ...
Страница 126: ... 126 139 Delimiter CR 0Dh End of packet ...