IV. Control Commands
6. Typical procedure example
The following is a sample of procedures to control the monitor, these are examples of "Get parameter",
"Set parameter" and "Save current settings".
6.1. How to change the “Backlight” setting.
Step 1. The controller requests the Monitor to reply with the current brightness setting and capability
to support this operation. (Get parameter)
Header
Message
Check code
Delimiter
SOH-'0'-Monitor ID-
'0'-'C'-'0'-'6'
STX-'0'-'0'-'1'-'0'-ETX
BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get a value.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'C' (43h): Message type is "Get parameter command".
'0'-'6' (30h, 36h): Message length is 6 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the OP code page 0).
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 2. The monitor replies with current Backlight setting and capability to support this operation.
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'D' (44h): Message Type is "Get parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Backlight max value is 100(0064h).
'0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): Current Backlight setting is 50(0032h) .
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Header
Message
Check code
Delimiter
SOH-'0'-'0'-Monitor ID-
'D'-'1'-'2'
STX-'0'-'0'-'0'-'0'-'1'-'0'-'0'-'0'
-'0'-'0'-'6'-'4'-'0'-'0'-'3'-'2'-ETX
BCC
CR
Содержание X754HB
Страница 6: ... 6 139 Please refer Controlling the LCD monitor via LAN control on User s manual ...
Страница 14: ... 14 139 4 4 Delimiter Packet delimiter code ASCII CR 0Dh Header Message Check code Delimiter ...
Страница 17: ... 17 139 18th byte ETX End of Message ASCII ETX 03h ...
Страница 51: ... 51 139 CR 0Dh End of packet ...
Страница 77: ... 77 139 Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...
Страница 89: ... 89 139 Delimiter CR 0Dh End of packet ...
Страница 98: ... 98 139 Delimiter CR 0Dh End of packet ...
Страница 102: ... 102 139 Delimiter CR 0Dh End of packet ...
Страница 104: ... 104 139 Refer to the section 4 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...
Страница 106: ... 106 139 Delimiter CR 0Dh End of packet ...
Страница 108: ... 108 139 Delimiter CR 0Dh End of packet ...
Страница 110: ... 110 139 Delimiter CR 0Dh End of packet ...
Страница 112: ... 112 139 Delimiter CR 0Dh End of packet ...
Страница 115: ... 115 139 Delimiter CR 0Dh End of packet ...
Страница 118: ... 118 139 Delimiter CR 0Dh End of packet ...
Страница 124: ... 124 139 Delimiter CR 0Dh End of packet ...
Страница 126: ... 126 139 Delimiter CR 0Dh End of packet ...