SV8100 System Design Considerations
This document is an aid for network designers and pre-sales in designing an
SV8100 taking some system boundaries and design experience into account.
Effect of the considerations for the end user are indicated when applicable.
Traffic Capacity
S
ECTION
1
S
INGLE
N
ODE
S
YTEMS
These Considerations also apply and have effect on multi node
configurations
1.1
Traffic performance
a. Busy Hour Call Attempts
i The BHCA value for a single CPU is theoretical 5120.
This value is the value without any Busy Lamp Fields
(BLF)/TAPI/OAI/CTI load, but does include SMDR.
ii End User Experience when traffic exceeds the
boundaries: see BHCA exceeded
1.2
IP Boundaries
a. The max total of non-blocking IP extensions/IP Trunks
supported per Node is 128. This includes any type of IP:
proprietary I-SIP for DT700 series, standard SIP (so e.g.
WiFi)
Examples:- If IP extensions and TDM trunks. Can have128 IP
Extensions.
If TDM extensions and IP Trunks. Can have 128 IP Trunks
If IP Extensions and IP Trunks. Can have a Total of 128 e.g. 64 IP
Extensions and 64 IP Extensions
i End User Experience: see Lack of IPLA resource
Содержание Univerge SV8100
Страница 1: ...Configuration Guide Issue 2 00...
Страница 2: ......
Страница 4: ......
Страница 12: ...Issue 2 00 UNIVERGE SV8100 R 6 Regulatory NOTES...
Страница 34: ...Issue 2 00 UNIVERGE SV8100 1 14 Introduction to UNIVERGE SV8100 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 102: ...Issue 2 00 UNIVERGE SV8100 2 68 Features THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 112: ...Issue 2 00 UNIVERGE SV8100 3 10 Equipment THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 142: ...Issue 2 00 UNIVERGE SV8100 5 26 Hardware Specifications THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 149: ......
Страница 150: ...CONFIGURATION GUIDE NEC Unified Solutions Issue 2 00...