Table 3-5 Maximum Number of Packages Installed
Board
(Power Factor)
Maximum Number of Package Installed
9.5 inch
with CCPU
19 inch
with CCPU
19 inch
without
CCPU
4 x 19 inch
CD-ETIA (2)
2
3
3
12
CD-PVAA (1)
2
5
6
23
CD-RTB (2)
1
2
2
8
Table 3-6 Terminal Power Factor
Terminal Power Factor
19 inch Metal Chassis with Fan =<80
9.5 inch Plastic Chassis without Fan =<64
Item
Power Factor
DTL-24D-1 TEL
0.8
DTL-8LD-1 TEL
0.8
BHA-L UNIT
2
ADA-L UNIT
2
APR UNIT
2
BCH-L (BK) UNIT
2
PSA-L UNIT
1.2
8LK-L UNIT
0
DCL-60-1 CONSOLE
2
ITL-320C-1 TEL
6
ITL-24D-1 TEL
4
ITL-2E-1 TEL
4
ITL-6DE-1 TEL
4
SLT
Standard (-28V) : 0.8
Long Line (-48V) : 2
PGD(2)-U10 ADP
2