For PRI PKG Setup
SLOT Number
1 ~ 12
Item No.
Item
Input Data
Description
Default
01
ISDN Line Mode
0 = No Setting
1 = T-Point
2 = S-Point
6 = S-Point (Leased Line)
1
02
Logical Port Number
[0 : No Setting] = 0
[1 : T-Point] = 1 ~ 128
[2 : S-Point] = 1 ~ 128
[6 : S-Point (Leased Line)] = 1 ~ 128
The start port num-
ber of a PRI line is
displayed.
0
03
CRC Multi-frame (CRC4)
0 = off
1 = on
1
04
Layer 3 Timer Type
1 ~ 5
Each timer value of
Layer 3 is set up for
each type in Program
81-06 (T-Bus)
1
05
CLIP Information
0 = No
1 = Yes
Based on this setting, the
system includes a Pre-
sentation Allowed (1) or
Presentation Restricted
(0) in the Setup message
to allow or deny the Call-
ing Party Number. Pro-
gram 15-01-04 must also
be set to 1 if this option is
enabled.
1
06
Length of Cable
0 = Level 1
1 = Level 2
2 = Level 3
3 = Level 4
4 = Level 5
2
07
S-point DDI digits
0 - 4
0
08
Dial Sending Mode
0 = Enbloc Sending
1 = Overlap Sending
ISDN Protocol definition
0
09
Dial Information Element
0 = Keypad Facility
1 = Called Party Number
ISDN Protocol definition
Only when Dial Sending
Mode (10-03-08) is set for
1 (Overlap Sending).
0
10
Master/Slave System
0 = Slave System
1 = Master System
If set to 0, system is
synchronized to network
clock. If set to 1, system
is not synchronized to the
network clock.
0
13
Loss-Of-Signal Detection
Limit
0 = Level 0 (lowest sensitivity)
1 = Level 1
2 = Level 2
3 = Level 3
4 = Level 4
5 = Level 5
6 = Level 6
7 = Level 7 (highest sensitivity)
If the transmit/receive
voltage is less than the
setting in 10-03-13, the
system considers this as
Loss-Of-Signal and the
PRI does not come up.
Note that there are differ-
ent values based on the
setting in 10-03-12 for the
PRI.
2
14
Service Protocol for S-point
0 = Keypad facility
1 = Specified Protocol for Aspire sys-
tem
0
15
Call Busy Mode for S-point
0 = Alerting
1 = Disconnect
0
SL2100
ISSUE 2.0
2-12
Program 10 : System Configuration Setup
Program
10
Содержание UNIVERGE SL2100
Страница 1: ...Programming Manual GVT 010795 301 00 NA ISSUE 2 0 ...
Страница 14: ...MEMO SL2100 ISSUE 2 0 xii Programming Manual ...
Страница 24: ...MEMO SL2100 ISSUE 2 0 1 10 Introduction ...
Страница 76: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 52 Program 10 System Configuration Setup Program 10 ...
Страница 115: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 91 Program 11 ...
Страница 144: ...Conditions None Feature Cross Reference None SL2100 ISSUE 2 0 2 120 Program 14 Trunk Basic Setup Program 14 ...
Страница 164: ...Conditions None Feature Cross Reference None SL2100 ISSUE 2 0 2 140 Program 15 Extension Basic Setup Program 15 ...
Страница 171: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 147 Program 15 ...
Страница 184: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 160 Program 15 Extension Basic Setup Program 15 ...
Страница 198: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 174 Program 15 Extension Basic Setup Program 15 ...
Страница 220: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 196 Program 20 System Option Setup Program 20 ...
Страница 237: ...Feature Cross Reference Caller ID ISSUE 2 0 SL2100 Programming Manual 2 213 Program 20 ...
Страница 251: ...Feature Cross Reference Conference Remote ISSUE 2 0 SL2100 Programming Manual 2 227 Program 20 ...
Страница 261: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 237 Program 20 ...
Страница 275: ...Conditions None Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 251 Program 20 ...
Страница 319: ...Feature Cross Reference Direct Inward Dialing DID ISSUE 2 0 SL2100 Programming Manual 2 295 Program 22 ...
Страница 343: ...Feature Cross Reference Call Forwarding Off Premise ISSUE 2 0 SL2100 Programming Manual 2 319 Program 24 ...
Страница 425: ...Feature Cross Reference Automatic Call Distribution ACD ISSUE 2 0 SL2100 Programming Manual 2 401 Program 41 ...
Страница 436: ...Feature Cross Reference Hotel Motel SL2100 ISSUE 2 0 2 412 Program 42 Hotel Setup Program 42 ...
Страница 443: ...Feature Cross Reference Hotel Motel ISSUE 2 0 SL2100 Programming Manual 2 419 Program 42 ...
Страница 483: ...Conditions None Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 459 Program 47 ...
Страница 485: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 461 Program 47 ...
Страница 503: ...Conditions None Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 479 Program 47 ...
Страница 506: ...Conditions None Feature Cross Reference None SL2100 ISSUE 2 0 2 482 Program 47 InMail Program 47 ...
Страница 546: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 522 Program 82 Basic Hardware Setup for Extension Program 82 ...
Страница 551: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 527 Program 82 ...
Страница 568: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 544 Program 84 Hardware Setup for VoIPDB Program 84 ...
Страница 571: ...Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 547 Program 84 ...
Страница 575: ...Conditions None Feature Cross Reference None ISSUE 2 0 SL2100 Programming Manual 2 551 Program 84 ...
Страница 578: ...Conditions None Feature Cross Reference None SL2100 ISSUE 2 0 2 554 Program 84 Hardware Setup for VoIPDB Program 84 ...
Страница 616: ...Conditions None Feature Cross Reference None SL2100 ISSUE 2 0 2 592 Program 90 Maintenance Program Program 90 ...
Страница 618: ...Feature Cross Reference None SL2100 ISSUE 2 0 2 594 Program 90 Maintenance Program Program 90 ...
Страница 624: ...Feature Cross Reference Traffic Reports SL2100 ISSUE 2 0 2 600 Program 90 Maintenance Program Program 90 ...
Страница 677: ...MEMO ISSUE 2 0 SL2100 Programming Manual 2 653 ...
Страница 678: ...Programming Manual NEC Corporation ISSUE 2 0 ...