118
This section describes the simple maintenance procedures you should follow to clean the filters, the projection window,
the cabinet, and to replace the lamp and the filters.
1
Cleaning the Filters
The air-filter sponge keeps dust and dirt from getting inside the projector and should be frequently cleaned. If the filter
is dirty or clogged, your projector may overheat.
WARNING
• Do not use a spray containing flammable gas to get rid of accumulated dust and dirt on the filters. It may cause
of fire.
NOTE: The message for filter cleaning will be displayed for one minute after the projector is turned on or off. When the message is
displayed, clean the filters. The time to clean the filters is set to [5000 H] at time of shipment.
To cancel the message, press any button on the projector cabinet or the remote control.
The two-layer filter on the projector improves cooling and dust-proof capabilities.
The outsides (intake side) of the first and second layer filters remove dust.
To clean the filter, detach the filter unit and the filter cover.
CAUTION
• Before cleaning the filters, turn off the projector, disconnect the power cord and then allow the cabinet to cool.
Failure to do so can result in electric shock or burn injuries.
1. Push the button rightward to release the filter cover and pull
it out.
Button
2. Remove the two filter cases.
Small filter case
Large filter case
Tab
Tab