CHAPTER 12 STANDBY FUNCTION
User’s Manual U12978EJ3V0UD
180
12.2 Standby Function Operation
12.2.1 HALT mode
(1) HALT mode
The HALT mode is set by executing the HALT instruction.
The operation status in the HALT mode is shown in the following table.
Table 12-1. HALT Mode Operation Status
Item
HALT Mode Operation Status
Clock generator
Oscillation enabled
CPU
Operation disabled
Port (output latch)
Remains in the state before the selection of HALT mode.
8-bit timer 00 (TM00)
Operation enabled
8-bit timer/event counter 01 (TM01)
Operation enabled
Watchdog timer
Operation enabled
USB function
Operation enabled
Serial interface
Operation enabled
Key return
Operation enabled
Note 1
External interrupt
Operation enabled
Note 2
Notes 1.
Operation is enabled only for pins set in key return mode register 00 (KRM00).
2.
Maskable interrupt that is not masked
Содержание switch