- 108 -
Provide cascade connection for FC Switch Modules according to the following procedure:
1.
Check the locations of FC Switch Modules subjected to cascade connection and confirm that SFP
modules are installed on the ports for the connection.
Install SFP modules if not installed.
2.
Check the internal settings of the additional FC Switch Modules to connect.
Zoning should not be set.
If set, always disable all zoning configurations to delete them completely.
After deleting the zone configurations, save the new zone configurations by using the "cfgSave"
command.
For how to delete zone information, see "Setting zoning" in "Appendix FC
Switch Module Setting Features".
If an additional introduced FC Switch Module is made cascade connection to
the FC Switch Modules in operation, delete the zone information only in the
additional FC Switch Module to connect.
If the Zone information of the FC Switch Module used in the system operated,
system failure or data destruction may occur. The Zone information of the FC
Switch Module in the system operated must not be deleted.
The Zone information set in the FC Switch Module operated is transmitted to
the FC Switch Module subjected to cascade connection and becomes
effective.
3.
Disable FC Switch Modules to be connected by using the "switchDisable" command.
WH040000557:admin>
WH040000557:admin> switchdisable
WH040000557:admin>
4.
Change the domain IDs of FC Switch Modules to be connected.
For how to change domain IDs, see the domain ID setting feature in
"Appendix FC Switch Module Setting Features".
5.
Connect FC Switch Modules with each other through an FC cable.
6.
Make disabled FC Switch Modules effective by using the "switchEnable" command.
WH040000557:admin>
WH040000557:admin> switchenable
WH040000557:admin>
Содержание SIGMABLADE N8406-019
Страница 2: ...2 N8406 019 N8406 020 FC N8406 019 N8406 020 FC SIGMABLADE SIGMABLADE...
Страница 6: ...6...
Страница 8: ...8 OFF NF9330 SF02 SFP 1 20cm SFP...
Страница 9: ...9 SIGMABLADE...
Страница 12: ...12 SIGMABLADE SIGMABLADE SIGMABLADE...
Страница 14: ...14 N8406 019 N8406 020 FC Windows 3 6...
Страница 16: ...16 SIGMABLADE...
Страница 18: ...18...
Страница 24: ...24 1 ID or ID 3 Status Status 3 ACT 1 1 Status...
Страница 25: ...25 Status LED LED SFP SFP Fibre Channel 1 Disable 0 25 Speed LED LED 1Gbps 2Gbps 4Gbps 1Gbps...
Страница 27: ...27 4 SIGMABLADE SFP FC SFP FC FC FC FC...
Страница 28: ...28 4 1 SIGMABLADE SIGMABLADE Linkup FC SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE...
Страница 29: ...29 SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE...
Страница 30: ...30 SIGMABLADE SIGMABLADE SIGMABLADE 10 Fibre Channel SIGMABLADE SIGMABLADE CPU Fibre Channel...
Страница 31: ...31 SIGMABLADE FC FC FC FC FC FC SFP SFP 4 2 SFP SFP...
Страница 32: ...32 SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE FC 4...
Страница 34: ...34 SFP SFP SFP SFP SFP N8406 FC NF9330 SF02 SFP N8406 FC...
Страница 35: ...35 4 3 FC PASSWORD Domain ID Principal Selection Mode FC...
Страница 65: ...65 1 Principal Principal Principal Selection Mode 2 1 1 Fabric I O 2 2 2 Fabric I O 1 2 1 2...
Страница 66: ...66 3 1 Fabric I O 2 2 2 Fabric I O 2 3 2 3 1 1...
Страница 67: ...67 3 3 1 Fabric I O 4 1 Fabric I O 2 3 1 2 3 4 1...
Страница 68: ...68 2 2 2 Fabric I O 3 4 1 Fabric I O 2 3 4 1 2 3 4 1...