375
CHAPTER 17 SERIAL INTERFACE CHANNEL 0 (
µ
PD78054Y Subseries)
(c) Interrupt timing specification register (SINT)
SINT is set by the 1-bit or 8-bit memory manipulation instruction.
RESET input sets SINT to 00H.
R/W
WAT1
WAT0
Interrupt control by wait (See
Note 2
)
0
0
Interrupt service request is generated on rise of 8th SCK0 clock cycle (clock output is high
impedance).
0
1
Setting prohibited
1
0
Used in I
2
C bus mode (8-clock wait)
Generates an interrupt service request on rise of 8th SCL clock cycle. (In case of master device,
SCL pin is driven low after output of 8 clock cycles, to enter the wait state. In case of slave device,
SCL pin is driven low after input of 8 clock cycles, to require the wait state.)
1
1
Used in I
2
C bus mode (9-clock wait)
Generates an interrupt service request on rise of 9th SCL clock cycle. (In case of master device,
SCL pin is driven low after output of 9 clock cycles, to enter the wait state. In case of slave device,
SCL pin is driven low after input of 9 clock cycles, to require the wait state.)
R/W
WREL
Wait release control
0
Indicates that the wait state has been released.
1
Releases the wait state. Automatically cleared to 0 after releasing the wait state. This bit is used to release
the wait state set by means of WAT0 and WAT1.
R/W
CLC
Clock level control
0
Used in I
2
C bus mode. In cases other than serial transfer, SCL pin output is driven low.
1
Used in I
2
C bus mode. In cases other than serial transfer, SCL pin output is set to high impedance. (Clock
line is held high.) Used by master device to generate the start condition and stop condition signals.
R/W
SVAM
SVA bits used as slave address
0
Bits 0 to 7
1
Bits 1 to 7
R/W
SIC
INTCSAI0 interrupt source selection
Note 3
0
CSIIF0 is set to 1 after end of serial interface channel 0 transfer.
1
CSIIF0 is set to 1 after end of serial interface channel 0 transfer or when stop condition is detected.
R
CLD
SCL pin level (See
Note 4
)
0
Low level
1
High level
Notes 1. Bit 6 (CLD) is read-only.
2. When the I
2
C bus mode is used, be sure to set 1 and 0, or 1 and 1 in WAT0 and WAT1, respectively.
3. When using the wake-up function in I
2
C mode, be sure to set SIC to 1.
4. When CSIE0 = 0, CLD is 0.
Remark
SVA
: Slave address register
CSIIF0 : Interrupt request flag corresponding to INTCSI0
CSIE0 : Bit 7 of serial operating mode register 0 (CSIM0)
<6>
<5>
<4>
<3>
<2>
1
0
7
Symbol
SINT
0
CLD
SIC
FF63H 00H R/W
Note1
Address After Reset R/W
SVAM CLC WREL WAT1 WAT0
Содержание PD78052
Страница 2: ...2 MEMO ...
Страница 8: ...8 MEMO ...
Страница 16: ...16 MEMO ...
Страница 36: ...36 MEMO ...
Страница 158: ...158 MEMO ...
Страница 174: ...174 MEMO ...
Страница 240: ...240 MEMO ...
Страница 260: ...260 MEMO ...
Страница 340: ...340 MEMO ...
Страница 392: ...392 MEMO ...
Страница 438: ...438 MEMO ...
Страница 482: ...482 CHAPTER 20 REAL TIME OUTPUT PORT MEMO ...
Страница 510: ...510 MEMO ...
Страница 524: ...524 MEMO ...
Страница 560: ...560 MEMO ...
Страница 576: ...576 MEMO ...
Страница 598: ...598 MEMO ...
Страница 602: ...602 MEMO ...