GWP-G22906
2) Adjust some volumes of “V OUTPUT” for OUTPUT meter on the LCD
display and TX O/P fault level as referred to the adjustment procedure(1).
(Refer to Table 4-1)
3) Adjust some volumes of “V REFLECT” for REFLECT meter on the LCD
display and TX R/P fault level as referred to the adjustment procedure(2).
(Refer to Table.4-2)
Table 4-1 Adjustment procedure (OUTPUT)
Setting Item
SW/VR
Set Value or Method of Adjustment
(1) USE/SET
SW1113
Set to USE.
(refer to right figure )
(2) Meter 0
Adjustment
VR1102
Adjust each meter swing to 0.
(3) OUTPUT Meter
CAL
VR1103
Adjust to meter reading is 100% when the
output power is at the rated level.
(4) USE/SET
SW1113
Set to SET.
(refer to right figure )
(5) HIGH Alarm
SW1107
Set to HIGH.
(refer to right figure )
(6) HIGH set
VR1106
Adjust meter to set fault value.
Set to normal power
+
0.8dB.
(7) LOW Alarm
SW1107
Set to LOW.
(refer to right figure )
(8) LOW set
VR1107
Adjust meter swing to set fault value.
Set to standard level
−
1dB.
(9) USE/SET
SW1113
Set to USE.
(refer to right figure )
4 - 17
Содержание PCN-1815SSQN/1Cx2
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ...TV TRANSMITTER ...
Страница 26: ...SECTION 1 CAUTION AND SAFETY ...
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ...SECTION 2 GENERAL INFORMATION ...
Страница 53: ...SECTION 3 FUNCTIONAL DESCRIPTION ...
Страница 88: ...SECTION 4 OPERATION AND ADJUSTMENTS ...
Страница 94: ...GWP G22906 Fig 4 3 Transmitter Rear view 9 4 6 ...
Страница 108: ...SECTION 5 MAINTENANCE ...