ROI-S04488
OPERATION
3-29
3.3 Equipment Start-up and Shut-down
Procedure for equipment start-up and shut-down are described below.
3.3.1 Start-up
Test Equipment and Accessories Required
• Agilent 34401A Digital Multimeter (or equivalent) with Test Leads
Step
Procedure
1
Check that the LINE IN voltage is between
+
20 V to
+
60 V/
−
20 V to
−
60 V with the digital multimeter, before connecting
the power connector to the IDU,
Note: The range of DC power input depends on system
requirement.
2
Turn on the POWER switch on the IDU (refer to Fig. 3-5),
Note: In 1+ 1 system,
When neither No.1 nor No.2 channel is working, first set
the OPR SEL No.1-No.2 switch on the IDU to neutral
position or No.1 or No.2 to be powered up side.
When either No.1 or No.2 channel is working, set the
OPR SEL No.1-No.2 switch on the IDU to the working
channel side, then, turn on the power switch of the not
working channel.
3
Allow equipment to warm up for at least 30 minutes.
Fig. 3-5 Front View of the IDU for Powering Up
RESET
IDU
ODU
PWR
PASOLINK
MAINT
SELV
−
+
LA PORT
LA PORT
DSC/ASC
LA PORT
NMS/RA
CALL
OPR
FUSE (7.5A)
FUSE (7.5A)
EOW
MS LAN
RX
RX
TX
TX
OPR
ALM
SEL
No.1
No.2
1
2
−
PASOLINK
RESET
RESET
IDU
ODU
PWR
PASOLINK
MAINT
SELV
−
+
LA PORT
NMS/RA
NMS LAN
CALL
RESET
MAINT
IDU
ODU
SELV
−
PWR
FUSE (7.5A)
EOW
PASOLINK
+
IDU for 1+0 System
IDU for 1+1 System
No.1 Power Switch
No.2 Power Switch
Power Switch
OPR SEL No.1 - No.2 Switch
LINE IN Connector
LINE IN Connector
LINE IN Connector
Содержание PASOLINK
Страница 1: ...DIGITAL MICROWAVE RADIO SYSTEM PASOLINK Training Course ...
Страница 16: ......
Страница 17: ...B 1 1 IDU ...
Страница 18: ......
Страница 68: ...Pasolink Digital microwave radio system Installation guide ...
Страница 79: ...NEC PASOLINK installation procedure January 2002 Terminating Coaxial Baseband Signal Cable with BNC Connector ...
Страница 80: ...NEC PASOLINK installation procedure January 2002 Terminating Coaxial IF Signal Cables with N P Connector ...
Страница 81: ...NEC PASOLINK installation procedure January 2002 ...
Страница 82: ...NEC PASOLINK installation procedure January 2002 Terminating Power Supply Cables with Molex Connector ...