GENERAL
ROI-S02775
1-6
1.2 Equipment Performance
The performance characteristics of the IDU are listed in Table 1-1.
Table 1-1 Performance Characteristics of IDU
Data signal interface (between IDU and DTE)
Bit rate:
• 2.048 Mbps ±50 ppm (2 MB
x
2/2 MB
x
4/2 MB
x
8/2 MB
x
16 system)
• 8.448 Mbps ±30 ppm (8 MB
x
1 system)
• 34.368 Mbps ±20 ppm (34 MB
x
1 system)
Level:
Meets specifications of ITU-T G.703
Code format:
High density bipolar-3 (HDB-3)
Impedance:
75 ohms, unbalanced or
120 ohms, balanced
Modulation method:
4-phase shift keying (4 PSK) system
Demodulation method:
Quasi-coherent detection
IF signal interface (between IDU and ODU)
Signal frequency
TX:
850 MHz
RX:
70 MHz
Signal level
IF output:
−
5 dBm, nominal
IF input:
−15
to 0 dBm (at , RX IN), varies with cable length
(maximum cable length (8D-FB): l=300 m)
Impedance:
50 ohms, unbalanced
Insertion loss:
15 dB at 70 MHz (l=300 m)
45 dB at 850 MHz (l=300 m)
Orderwire frequency
Output:
468 kHz, amplitude modulation (AM)
Input:
450 kHz, AM
Power supply:
−
43 V DC (through) at IF IN/OUT
Control/Monitor signal frequency:
10 MHz, amplitude shift keying (ASK) (at IF IN/OUT)
Содержание PASOLINK
Страница 1: ...DIGITAL MICROWAVE RADIO SYSTEM PASOLINK Training Course ...
Страница 16: ......
Страница 17: ...B 1 1 IDU ...
Страница 18: ......
Страница 68: ...Pasolink Digital microwave radio system Installation guide ...
Страница 79: ...NEC PASOLINK installation procedure January 2002 Terminating Coaxial Baseband Signal Cable with BNC Connector ...
Страница 80: ...NEC PASOLINK installation procedure January 2002 Terminating Coaxial IF Signal Cables with N P Connector ...
Страница 81: ...NEC PASOLINK installation procedure January 2002 ...
Страница 82: ...NEC PASOLINK installation procedure January 2002 Terminating Power Supply Cables with Molex Connector ...