8. Appendix
193
Indicator Message (Error message)
POWER
STATUS
LIGHT
TEMP.
Projector status
Procedure
A button has been
pressed while the [CON-
TROL PANEL LOCK] is
activated.
The [CONTROL PANEL
LOCK] is activated. The
setting must be canceled
to operate the projector.
(
→
page
)
Blue
(Light)
Orange
(Light)
Status varies
Off
ID numbers for the
projector and the remote
control do not match.
Check the [CONTROL ID]
(
→
page
)
Temperature problem (In
the Forced ECO)
Ambient temteprature
is high. Lower the room
temperature.
Blue
(Light)
Off
Orange
(Light)
Orange
(Light)
Temperature problem
Ambient temperature
is out of the operation
temperature. Check if any
obstruction stays near the
exhaust vent.
Red
(Blink*
7
)
Off
Off
Off
Error requiring service
support
Contact your dealer or
service personnel. Make
sure to check and inform
indicator status for asking
to repair.
Red
(Light)
Status varies
Status varies
Off
*7 Repetition to light on for 0.5 seconds / off for 0.5 seconds
When the thermal protector is activated:
When inside temperature of the projector becomes too high or low, the POWER indicator start to
red blink in a short cycle. After this happened, the thermal protector will activate and the projector
may be turned off.
In this case, please take the below measures:
• Pull out the power plug from the wall inlet.
• Place the projector in cool place if it has been placed in high ambient temperature.
• Clean the exhaust vent if dust has accumulated on.
• Leave the projector for about one hour until inside temperature gets lower.