59
3.32
[ 078-2. RUNNING STATUS REQUEST ]
Gets the information about the operation status of the projector.
Command
00h 85h 00h 00h 01h 01h 87h
Response
4
When the command succeeds
20h 85h
<ID1>
<ID2>
10h
<DATA01>
-
<DATA16>
<CKS>
Data part
Item
Description
DATA01 - 02
Reserved for the system
DATA03
Power status
00h
Standby
FFh
Not supported
01h
Power on
-
-
DATA04
Cooling process
00h
Not executed
FFh
Not supported
01h
During execution
-
-
DATA05
Power On/Off process
00h
Not executed
FFh
Not supported
01h
During execution
-
-
DATA06
Operation status
00h
Standby (Sleep)
0Fh
Standby (Power saving)
04h
Power on
10h
Network standby
05h
Cooling
FFh
Not supported
06h
Standby (error)
-
-
DATA07 - 16
Reserved for the system
4
When the command fails
A0h 85h
<ID1>
<ID2>
02h
<ERR1>
<ERR2>
<CKS>