NC1500C
4. LCD Menu
New Lamp house
When the lamp house is replaced, reset the lamp house time and select the lamp house. This
menu is active in standby mode only.
←
Displays the currently selected item with asterisk (*).
←
Displays the setting
←
Select the items for which the usage times are cleared.
←
Displays the currently selected item with asterisk (*).
←
Displays the setting
←
Select the mode for lamp house usage time.
Single
To set the mode in which lamp house is not replaced (Single mode)
Multi
To set the mode in which the lamp houses are alternately replaced for
use (Multi-mode).
- Lamp house 1: To use the lamp house 1
- Lamp house 2: To use the lamp house 2
House
To set the mode in which lamp house is not replaced (Single mode)
House1
When multi-mode lamp 1 is used
House2
When multi-mode lamp 2 is used
Usage Clear
Reset the lamp house usage time.
Usage Mode
Set the mode for lamp house usage time.
Bulb Alignment
Use this for lamp bulb alignment adjustment.
Press [LAMP-] in [LAMP CTL] to clear the maximum value of Peakhold.
←
Display the maximum value of the lamp light quantity input.
←
Display the current input for lamp light quantity.
D-47