ESX Operation and Configuration 3-7
Unused disks:
- vmhba110500:C0:T0:L0
(After verifying the isolation of the specified disk from the RAID configuration
(“after confirming that Unused disks” is displayed), replace the hard disk.
Wait approximately five minute before the system starts to resynchronize. If there
is no automatic synchronization, manually restore the disk with the below
procedure.)
# ./mpmadm -l
mpm0 [1/2]
|_ vmhba100500:C0:T0:L0 [ in_sync ]
(Check if the replaced disk is recognized by the system.)
# ./mpmadm -l
mpm0 [1/2]
|_ vmhba100500:C0:T0:L0 [ in_sync ]
Unused disks:
- vmhba110500:C0:T1:L0
(If the system does not synchronize in the replaced disk automatically, execute
the below command to restore to the RAID configuration manually.)
# ./mpmadm -a mpm0 vmhba110500:C0:T1:L0
Successfully added disk vmhba110500:C0:T1:L0 to volume mpm0.
(Check if the resynchronization process is started.)
# ./mpmadm -l
mpm0 [2/2] recover=0.6% (455808/71484736) finish=18.1min (65115K/s)
|_ vmhba110500:C0:T1:L0 [ syncing ]
|_ vmhba100500:C0:T0:L0 [ in_sync ]
(Perform restoration (RECOVERY) to each RAID devices (mpm). After a while,
check the Status with the below command. “syncing” shows to be in the process
of restoring.)
# ./mpmadm -l
mpm0 [2/2]
|_ vmhba110500:C0:T1:L0 [ in_sync ]
|_ vmhba100500:C0:T0:L0 [ in_sync ]
(When the each RAID device Status is “in_sysnc” and Raid device( mpm ) is not
displasyed, the RAID configuration is restored normally. This ends the disk
replacement procedure.)
Содержание N8800-149F
Страница 18: ...ix THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 45: ...General Description 2 9 Rear View R320a E4 R320a M4...
Страница 48: ...2 12 General Description CPU IO Module R320a E4 top cover removed R320a M4 top cover removed 1 PCI Riser card...
Страница 80: ...3 14 ESX Operation and Configuration This page is intentionally left blank...
Страница 96: ...4 16 System Configuration IMPORTANT Wake On LAN environment is unavailable on ESX4 0...
Страница 97: ...System Configuration 4 17 Security Move the cursor onto Security to display the Security menu...
Страница 110: ...4 30 System Configuration Exit Move the cursor onto Exit to display the Exit menu...
Страница 122: ...4 42 System Configuration This page is intentionally left blank...
Страница 150: ...5 28 Installing and Using Utilities This page is intentionally left blank...
Страница 215: ...System Upgrade 8 31 Riser Card PCI 3 PCI 4 PCI 1 PCI 2 R320a E4 PCI 1 PCI 2 R320a M4...