34
13.
Install the BBU into the previous PCI slot of the server and fix it with the screw.
14.
Connect the battery cable to the battery connector on the disk array controller.
15.
Install the removed side cover and power cords to recover the original state. Turn
on the power of the server.
16.
After OS is booted, check whether the BBU is recognized correctly. For the
checking procedure, see "2. Checking by Utility" in "Chapter 2 Installation of
BBU."
Notice
The battery pack provided as a maintenance part is not charged at all.
For such battery pack, the value of "Voltage" is set to "Now Reading..."
on WebPAM.
WebPAM may not able to recognize the battery pack if it is charged only
at the minimum level. If this occurs, charge the battery pack for three
hours or longer. Then reboot the server and try to recognize the battery
pack again by using WebPAM.
Check
The battery pack is recyclable. Contact your service representative for the
recycle.
Содержание N8103-93
Страница 22: ......
Страница 40: ...18 This page is intentionally left blank ...
Страница 58: ...36 This page is intentionally left blank ...