30
7.
After charging the BBU, make sure that the Current Write Policy (indicating write cache operation
status) is indicated as "Write Back."
Current Write Policy : Write Back
“Logical” tab
Default Write Policy : Write Back
“Properties” tab
Notice
The battery cell you have purchased is not charged at all. For such battery
cell, the [Current Write Policy] in [Properties] of [Logical] tab is indicated as
"Write Through" on MSM.
You can check the charged status of battery cell by selecting [Relative State
of Charge] or [Absolute State of Charge] in [Physical] tab
→
[Properties] on
MSM.
Tips
For details of the Write Policy, refer to the User’s Guide of the disk array
controller or MSM User’s Guide (online document in the CD-ROM coming with
the server).
Содержание N8103-100
Страница 22: ......
Страница 24: ...2 3 1 2 2 2 1...
Страница 25: ...3 4 1 1 2 1 3 1 4 1 Set up Date Y M...
Страница 26: ...4 5 1 2 3 4 1 2 3 XXX 4 N8103 100...
Страница 27: ...5 Y M Set up Date 6 5 5 6 6 6 1 6 2 2 2 NEC...
Страница 28: ...6 2 N8103 99 0ch 1 1 1...
Страница 29: ...7 1 2 X X X Y 2006 M 08 Y M Set up Date 2 2 64 3...
Страница 30: ...8 1 3 N8103 99 1 2 3...
Страница 31: ...9 1 2 3...
Страница 33: ...11 3 Logical Logical Virtual Disk 4 Properties Default Write Policy Logical Operations...
Страница 37: ...15 3 1 NEC NEC 2 2 1 MegaRAID Storage ManagerTM MSM 2 2 2 2...